Rheem GRA Série Instructions D'installation page 24

Table des Matières

Publicité

FIGURE 19
VENTILATION VERTICALE DIRECTE STANDARD
MODÈLE À FLUX VERS LE HAUT (TYPIQUE POUR LE FLUX VERS LE BAS)
EXTRÉMITÉ DE
5
VENTILATION
CONDUIT DE
VENTILATION
CONDUIT D'AIR DE
COMBUSTION
NOTES:
1
LE CONDUIT D'AIR DE COMBUSTION DOIT
ÊTRE DANS UN ENDROIT SOUMIS À LA
MÊME PRESSION QUE LE CONDUIT DE
VENTILATION.
2
AUGMENTEZ LA DISTANCE
MINIMUM DE 12 PO AU TOIT SELON LE
NIVEAU DE NEIGE, LE CAS ÉCHÉANT.
3
SI VOUS UTILISEZ DES CONDUITS DE
VENTILATION DE 3 POUCES POUR ALLER DE
LA FOURNAISE AU TOIT, RÉDUISEZ LA
CONDUITE À 2 POUCES AVANT DE PASSER À
TRAVERS LE TOIT. UTILISEZ UNE LONGUEUR
MAXIMUM DE 18 POUCES DE CONDUIT DE 2
POUCES DE DIAMÈTRE.
4
LES CONDUITS VERTICAUX DOIVENT ÊTRE
ATTACHÉS TOUS LES 6 PIEDS.
5
TERMINAISON DE LA VENTILATION -
UTILISEZ UN TUYAU PCV DE 2 POUCES SUR
LES MODÈLES 90 000 À 120 000 BTUH.
RÉDUISEZ LE TUYAU À 1,5 POUCES SUR LES
12 DERNIERS POUCES POUR LES MODÈLES
45 000 À 75 000 BTUH.
6
HAUTEUR MAXI DE VENTILATION AU
DESSUS DU TOIT : 30 PO.
FIGURE 20
VENTILATION HORIZONTALE DIRECTE STANDARD
MODÈLE À FLUX VERS LE HAUT (TYPIQUE POUR LE FLUX VERS LE BAS)
RÉSERVOIR D'AIR
CONDUIT DE VENTILATION
CONDUIT D'AIR DE COMBUSTION
N.B. :
LES CONDUITS HORIZONTAUX
1
DOIVENT ÊTRE ATTACHÉS TOUS
LES 4 PIEDS.
2
SI VOUS UTILISEZ DES CONDUITS DE
VENTILATION DE 3 POUCES RÉDUISEZ LA
CONDUITE À 2 POUCES AVANT DE PASSER
À TRAVERS LE MUR.
3
UTILISEZ UNE LONGUEUR MAXIMUM DE
18 POUCES DE CONDUIT DE 2 POUCES
DE DIAMÈTRE À L'INTÉRIEUR DU MUR.
4
DÉTAIL "A" - TERMINAISON DE LA
VENTILATION - UTILISEZ UN TUYAU PCV
DE 2 POUCES SUR LES MODÈLES 90 000
À 120 000 BTUH. RÉDUISEZ LE TUYAU À
1,5 POUCES POUR LES MODÈLES 45 000
À 75 000 BTUH.
5
AUGMENTEZ LA DISTANCE MINIMUM DE
12 POUCES AU SOL SELON LE NIVEAU DE
NEIGE, LE CAS ÉCHÉANT.
DÉTAIL "B", INSTALLEZ L'AUBE DE
6
DÉFLECTION DU VENT DANS LE
COUPLEUR PCV 2 POUCES EN POSITION
VERTICALE AVEC LA COLLE SOLVANT.
LE CONDUIT D'AIR DE COMBUSTION DOIT
ÊTRE DANS UN ENDROIT SOUMIS À LA
MÊME PRESSION QUE LE CONDUIT DE
VENTILATION.
24
SÉPARATION DE 3
POUCES MAX.
12"
CONDUIT D'AIR DE
COMBUSTION
12 POUCES DE
30 MAX
SÉPARATION
12 POUCES
MINIMUM AU-
LIGNE DE TOIT
DESSUS DU TOIT
3
RÉSERVOIR D'AIR
4
1
T DE 2 OU 3 PO. AVEC
TRAPPE D'ÉVACUATION
EXTRÉMITÉ D'AIR DE COMBUSTION
DÉTAIL B
1
CONDUIT D'AIR DE
COMBUSTION
2
12" MIN.
VENTILATION
RETOUR D'AIR
30 MAX
2
3
12"
4"
12 PO. MINIMUM AU-
DESSUS DU SOL
TRAPPE
SEE DETAIL B
CONNECTEZ AU
SYSTÈME
D'ÉVACUATION
RETOUR D'AIR
COUPLEUR PCV 2
VANE
POUCES
6
EXHAUST
MAX.
VENT
12"
MIN.
3"
VENTILATION
MAX.
12"
MIN.
LIGNE DU TOIT
5
5
INSTALLATIONS SUR TOIT INCLINÉ
12"
4
EXTRÉMITÉ DE VENTILATION
DÉTAIL A
VOIR DÉTAIL A
4"
5
3"
VENTILATION
4"
ENTRÉE
OPTIONNELLE
DÉTAIL C
DISTANCE ENTRÉE/VENTILATION
3"
CONDUIT D'AIR
DE COMBUSTION
12" MIN.
5
NIVEAU DE
NEIGE
I407
ENTRÉE
I407

Publicité