Troubleshooting
Pan-frying menu
Symptom
Probable cause
- Preheating time
- The pan has been moved away from the IR sensor.
takes too long.
- The pan bottom or top plate is stained.
- The actual
- Water, oil, or food was added during preheating.
temperature is
- The temperature on the bottom of the pan may vary from
different from the set
the set temperature depending on the type of pan.
temperature.
* If the actual temperature is incorrect adjust the
temperature with
Deep-frying menu
Symptom
Probable cause
- Preheating time
- The pot has been moved away from the IR sensor.
takes too long.
- The pot bottom or top plate is stained.
- The actual
- More than 800 g of oil has been added.
temperature is
- Hot oil, brown-coloured oil, murky oil, or oil filled with food
different from the set
sediment is used.
temperature.
- The oil temperature may vary from the set temperature
or the preheating time may take longer depending on the
type, material, and shape and size of the bottom of the pot.
* If the actual oil temperature is incorrect adjust the
temperature with
28
. (See page 20.)
. (See page 21.)
Error Indications
Indication
Probable cause
The indicator illuminates or flashes
- There is water or foreign objects on or around
the operation panel, or water or ingredients have
- In case of left or right front
boiled over.
IH heater
- The top plate has been touched for 3 seconds
- In case of left or right rear
or more. (Except operations which keys must be
IH heater
touched and held for 3 seconds or more, such as
rapid change of timer)
Operation keys error
detection
- No pot placed on the IH heater.
The indicator flashes.
- The pot being heated has been removed.
- The pot is not centred on the IH heater.
- An incompatible pot is used. (See page 16.)
- A metal kitchen tool, such as a knife or a spoon, is
on the top plate.
If they are not removed, the display goes out after a
minute then the main power turns off.
* The IR sensor may malfunction in a very bright
Undetected pot auto shutoff
environment, and
Small object auto shutoff
pot is placed on the IH heater.
For the following error indications, check the
cause and deal with it.
Heating automatically resumes after the cause
are eliminated.
Remove water or foreign objects. (If the
IH heater was turned off, perform the key
operation again.)
may not flash even though no
Turn off the IH heater, and then turn it on again.
29