Installation manual with technical data
1.0
Relationship to the authorities .................. 17
2.0
Technical data ............................................. 17
3.0
Installation .................................................18
4.0
Service ..........................................................21
5.0
Optional Equipment ...................................21
Figures .................................................................. 47
General use and maintenance manual
6.0
Safety precautions
7.0
Choice of fuel
8.0
Use
9.0
Maintenance
10.0
Operational problems - troubleshooting
Product:
On all our products there is a label
Jøtul
Room heater fired by solid fuel
indicating the serial number and
Standard
:
year. Write this number in the
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
:
place indicated in the installation
Flue gas temperature
:
Nominal heat output
:
Efficiency
:
instructions.
Operation range
:
Fuel type
:
Operational type
:
The appliance can be used in a shared flue.
Always quote this serial number
Country
Classification
Certificate/
Approved by
standard
when contacting your retailer or
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
Jøtul.
SP Swedish National
Testing and Research
EN
EUR
Intermittent
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those which refer to national
and European standards, must be observed when installing the
product.
Both an installation manual with technical data and a manual
on general use and maintenance are enclosed with the product.
The installation can only be used after it has been inspected by
a qualified inspector.
A name plate of heat-resistant material is affixed to the
product. This contains information about identification and
documentation for the product.
2.0 Technical data
Material:
Finish:
Fuel:
Log length, max.:
Operating range:
Flue outlet:
Flue pipe dimension:
Approx. weight:
Burn chamber:
-with short legs:
-with long legs:
- with pedestal
- with cast iron base:
- with cast iron base with glass: 160 kg
Optional extras:
Dimensions, distances:
Technical data according to EN 13240
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught:
Efficiency:
CO emission (13% O
):
2
Flue gas temperature:
Operational type:
By intermittent combustion one means normal use of a fireplace,
meaning that each fire should burn down to embers before new
firewood is added.
ENGlIsh
Cast iron
Black or grey varnish
Wood
30 cm
3.5-10.0 kW
Top, rear
Ø 1 5 0 m m , 1 7 7 c m
c ro s s
2
section
120 kg
130 kg
132 kg
141 kg
157 kg
Rotating set (Jøtul F 273), soap
stone panel, steel convection
panel, glass panel sides, glass
panel door, glass top plate, soap
stone top plate
See fig. 1
6.5 kW
5.5 g/s
12 Pa
77%@6,7kW
0.10%
327
C
o
Intermittent
17

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

F 271F 272F 273F 274F 275