Jenn-Air Euro-Style Série Instructions D'installation Et Guide D'utilisation Et D'entretien page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Install In-line Blower System
NOTE: The blower motor housing can be mounted using 4 holes
from either the inlet side or the outlet side of the blower.
Outlet Side
A
A
A. Mounting holes
Inlet Side
A
A. Mounting holes
1. Position the in-line blower motor housing in its mounting
location and mark the 4 mounting hole locations.
2. Drill 4 mounting pilot holes using a ³⁄₁₆" (4.8 mm) drill bit.
3. Attach the in-line blower motor housing to the mounting
location with 4 - 6 x 80 mm mounting screws and washers.
4. If it is removed, reinstall the blower motor assembly and
secure it with the screws previously removed.
5. If it is removed, reattach the motor electrical plug to the
connector on the blower motor assembly.
1. Determine and make all necessary cuts for the vent system.
2. Determine the location where the ¹⁄₂" (1.3 cm) wiring conduit
A
3. Drill a 1¹⁄₄" (3.2 cm) hole at this location.
4. Locate the electrical terminal boxes in the in-line blower
A
5. Remove the electrical knockout from the in-line blower
A
6. With the downdraft vent mounted, run the ¹⁄₂" (1.3 cm) wiring
7. Run the six 18 AWG wires through the ¹⁄₂" (1.3 cm) wiring
8. Install the conduit connectors and conduit to the in-line
9. Connect the vent system to the downdraft vent and in-line
Complete Preparation
IMPORTANT: When cutting or drilling into the floor, ceiling or
wall, do not damage electrical wiring or other hidden utilities.
will be routed through the floor, ceiling or wall between the
in-line blower and the downdraft vent.
housing and downdraft vent. Remove the terminal box covers
and set the covers and screws aside.
B
A
A. Electrical terminal box
B. Electrical knockout
housing and downdraft vent to prepare for the installation of
the UL listed or CSA approved ¹⁄₂" (1.3 cm) wiring conduit and
conduit connector.
conduit between the in-line blower motor housing and the
downdraft vent. Pull enough ¹⁄₂" (1.3 cm) wiring conduit to
allow for easy connection to the terminal boxes in the in-line
blower housing and downdraft vent.
conduit and conduit connectors and into the terminal boxes
on the in-line blower housing and downdraft vent. Leave
enough wire length in each terminal box to make the wiring
connections.
blower housing and downdraft vent electrical terminal boxes.
blower system and seal all joints with clamps.
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Euro-style jxd7836bs

Table des Matières