2. PRATICO adv 10000/15000 UV-C model:
i. Follow instructions from clause 1 to clause 3 of the previous paragraph, applying them to both overflow pipes.
III.b Sterilizer assembling
1. PRATICO adv 5000/7000 UV-C model:
WARNING: Prior to installation of PURE LIGHT UVC filter, it is recommended to insert the UVC lamp, included into the package,
following the instructions on the lamp replacement (see paragraph V-1).
i. Install the O-ring for the treaded coupling (3) on the screw nozzle (2), located on the body of PURE LIGHT UV-C filter.
ii. Insert the screw nozzle (2) of UV-C filter into the corresponding opening located at the side of PRATICO adv filter body.
iii. Acting from the internal side of PRATICO adv filter body, screw the intermediate coupling for mounting of UV-C filter/spray
EN
bar (4) on the UV-C filter screw nozzle to the stop.
iv. Screw the spray bar on the free end of the intermediate coupling for mounting of UV-C filter/spray bar (4), making sure
that the bar openings face down.
v. Fix the UV-C filter with the accessories for mounting of UV-C filter/PRATICO filter body (7). Act in the following order from the
internal part of the filter box: screw, washer, O-ring. Act in the following order from the external part of the filter box: washer, nut.
2. PRATICO adv 10000/15000 UV-C model:
WARNING: prior to installation of PURE LIGHT UV-C filter, it is recommended to insert the UVC lamp, included into the package,
following the instructions on the lamp replacement (see paragraph V-1).
i. Follow instructions in clauses 1-2 of the previous paragraph.
ii. Acting from the internal side of PRATICO adv filter body, screw the intermediate deflector for mounting of UV-C filter/spray
bar (5) on the screw nozzle of the UV-C filter to the stop. Make sure that the intermediate deflector is fixed parallel to the
bottom of the PRATICO adv filter body.
iii. Follow instructions in clauses 4-5 of the previous paragraph
III.c
LAYING OF FILTERING MATERIALS
1. PRATICO adv 3000/5000/7000 UV-C e 5000/7000 NO UV-C model:
i. Remove the clay (16)/ Bio-balls (17) from the package, put it inside the net supplied and place it on the bottom of the
container.
ii. Place the sponges inside the filter box, so that their hole is located on the overflow pipe. For this purpose, act in the
following order: coarse sponge, black (14), fine sponge, blue (13).
iii. Close the box with the cover.
2. PRATICO adv 10000/15000 UV-C model:
i. Unpack the Bio-balls (16) and place on the container bottom, trying to distribute them uniformly.
ii. Place the sponges inside the filter box, so that their hole is located on the overflow pipe. For this purpose, act in the
following order:
a. PRATICO adv. 10000 model: fine sponge, blue (13), Kinshi-mat sponge (17).
b. PRATICO adv 15000 model: fine sponge, blue (13), coarse sponge, black (14), Kinshi-mat sponge (17).
iii. Close the box with the cover.
III.d ASSEMBLING OF CONNECTING PARTS
WARNING:
• It is also recommended to place PURE LIGHT UV-C filter at the minimum distance of 2 m from the pond edge.(Figg. 7-8 pag. 7).
• For all PRATICO adv models: use corrugated hose, included into the package, for connection of pump with the UV-C filter,
preliminary installed on the PRATICO filter body. To ensure runoff of filtered water into the pond, it is necessary to use the
corrugated hose with the required diameter, taking into account that 2 adaptors, included into the package, allow mounting of
hoses with diameter 25 mm or 32 mm (Fig. 6 pag. 7).
1. PUMP --> UV-C FILTER:
i. Insert the elbow adaptor (13) into the corresponding screw ring.
ii. Connect the end of one of the 2 pieces of the corrugated hose (12) to the pump outlet intended for immersion into the pond.
32