Packaging Contains; Dn50 Tube Installation; Electrode Holder Installation; Connection Of The Electrode To The Pump - Mareva Premium pH Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.0 Packaging contains

1.
1,4 l/h pump
2.
2 m suction hose
3.
electrode holder for DN50 tube
4.
DN50 PVC adapter
5.
O.ring seal
6.
pH electrode Ref. 632001
7.
Electrode O.ring seal
8.
Distance spacers for DN63 tube assembly
9.
Electrode fixing ring nut
10.
Electrode holder screws
11.
Suction filter
12.
Fixing slide bracket with screws
13.
Buffer solution

3.1 DN50 tube Installation

- Install the DN50 PVC adapter on your hydraulic tube.
- Make sure that the 24 mm hole is upward positioned (do not orientate the hole downward or horizontal
ward).
- The DN50 PVC adapter have to be installed before the filter washing valve.
- To connect the DN50 PVC adapter to the pipe line use both gluing-connections or screw connections, at
your convenience.

3.2 Electrode holder installation

-
Verify the water flow direction before installing the electrode holder collar.
-
The electrode holder be vertically positioned, +-45° . (Never install the electrode holder in a way that
the electrode hole might be downward or horizontal ward oriented; a minimum angle of 45° is
necessary).

3.3 Connection of the electrode to the pump

-
Introduce the electrode connector into the pump outlet, and rotate anticlockwise a quarter of turn.
-
Gently pull the cable in order to verify that it is properly fixed.