Télécharger Imprimer la page

Data Storage - Balluff IO-Link BMF 415KW-HA W-5 Série Notice D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
BMF 415KW-HA _ _ _ -W-5- _ _ -...
Magnetic Field Sensors
6
IO-Link interface (continued)
6.5.9

Data storage

Index
Subindex Name
Data Storage
1
0x0003 (3)
2
3
4
5
Tab. 6-14: Data storage parameter
6.5.10 Access locks (Device Access Locks)
Using this standard parameter, it is possible to activate or
deactivate certain functions of the IO-Link device.
The BMF 415KW-HAKKI-... allows you to lock the function
of the parameter manager and the button. To do so, the
respective bit of the 2-byte value must be set to 1 (locked).
In order to unlock the function again, the bit is set to 0.
Index
Subindex Name
Device Access
Locks 0x000C
0
(12)
Tab. 6-15: Lock parameter
6.5.11 Profiles and functions (ProfileCharacteristic)
This parameter indicates which profile of the IO-Link device
is supported.
Index
Subindex Name
1
Profile
Characteristic
0x000D (13)
2
Tab. 6-16: Profiles and functions
www.balluff.com
Size
Command
1 byte
State Property
1 byte
Size
4 bytes
Parameter Checksum
4 bytes
Index List
29 bytes
Size
Access locks
2 bytes
Size
DeviceProfileID
Fixed Switching
2 bytes
Sensor
DeviceProfileID
Identification and
2 bytes
Diagnosis according to
Common Profile
Access
Values
Read Only
The Data Storage parameter is needed by
Read Only
the IO-Link master for the data storage
Read Only
function. This parameter cannot be user
Read Only
modified.
Read Only
Access
Values
Lock parameter access
Bit 0
(not supported)
Lock parameter management
(supported)
Bit 1
1 = locked
Read/Write
0 = unlocked
Bit 2
Lock button (not supported)
Lock local user interface (not
Bit 3
supported)
Bits 4...15
Reserved
Access
Values
Read Only
0x0002
Read Only
0x4000
english