Gas Requirement; Connecting To A Gas Cylinder; Important Safety Rules - Hendi 272602 Mode D'emploi

Masquer les pouces Voir aussi pour 272602:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GAS REQUIREMENTS
The pressure regulator and hose assembly to be used must conform to local standard codes.
Never use a gas cylinder with a damaged body, valve, collar, or foot ring.
A dented or rusty gas tank may be hazardous and should be checked out by a gas supplier.
Never connect this appliance to an unregulated gas source.
When the appliance is not in use, turn the gas cylinder OFF.
Always perform a leak test on gas connections whenever a cylinder is connected. If bubbles form
in the leak test solution, do not use. Never use a flame to test for leaks.

CONNECTING TO A GAS CYLINDER

Recommend to use 9kg gas cylinder or
Refer to your gas supplier for instructions on the use of your gas cylinder.
Only change gas cylinders outdoors or in a well ventilated area away from naked flames and any
other source of ignition.
The gas cylinder must always be used in an upright position.
Close the heater control knob by turning fully clockwise.
Close the gas cylinder tap and then attach the regulator onto the gas cylinder.
Tighten all connections firmly and with a spanner where appropriate. The cylinder should be
located on the cylinder base.
Check for leaks at all joints using soapy water. If a leak is found, tighten the joint and then re-test.

IMPORTANT SAFETY RULES

For use outdoors or in amply ventilated areas.
An amply ventilated area must have a minimum of 25% of
the surface area open.
The surface area is the sum of the walls surface.
The use of this appliance in enclosed areas can be
dangerous and is PROHIBITED.
Children and adults should be aware of the high operating
temperatures of areas above the post when operating this
heater. Children should be carefully supervised when in
the vicinity of the heater.
NEVER hang anything, including clothes or any other
flammable items, on this heater.
DO NOT operate this heater unless it is fully assembled
with its reflector in place.
Respect the minimum clearances from combustible materials.
refer to your gas supplier for suitable gas cylinder.
Ceiling /Overhang
1 mtr
1 mtr
17