Specifications
General Specifications
Display: 4 digit LCD, 9999 counts, with
annunciators, menu features and 41 segment
bargraph.
Polarity Indication: Automatic
Input overload indication: OL, -OL.
Low Battery Indication: B; less than 50 hours
battery life remain, accuracy is no longer
guaranteed
Display Update Rate: 2/sec, nominal; 20/sec for
bargraph.
Oper. Temp. 0 °C to +50 °C @ 0 to 75 % R.H.
Storage Temp: -20 °C to 60 °C @ 0 to 80 % RH,
battery removed
Altitude: 2000 meters - indoor/outdoor use
Temperature coefficient: 0.1 x (spec. accuracy)/
°C (0 °C to 18 °C and 28 °C to 50 °C)
Fuse: F 2 A/1500 V fuse (8 mm x 65 mm),
I.R. 30 kA – Amprobe p/n FP700
Power: Standard 9-volt battery, NEDA 1604, JIS
006P, IEC 6F22
Auto Power-Down: Meter powers down after
approximately 30 minutes of inactivity. Not in
Min/Max function.
Battery Life (typical): 150 hours, alkaline.
Backlight usage consumes extra power and will
decrease battery life significantly. Backlight
auto-off after approx. 60 seconds.
Dimensions, without holster (H x W x D): 200
x102 x59 mm (7.9 in x 4. 0 in x 2.3 in)
Weight (incl. battery): 642 g (22 oz)
Accessories: Heavy Duty Test leads with
threaded alligator clips, battery (installed),
hex wrench (inside holster), Holster with
Magne-Grip strap, Type K thermocouple probe
(TP255A), Temperature Adaptor (TA-1A) and
User Manual.
Case material: Reinforced, high-impact, fire
retardant thermoplastic
Safety: Meets EN 61010-1 Cat IV -1500 V dc or
1000 V ac. Class II. EN 60529:IP67
EMC: Meets EN 61326-1
EMC: This product complies with
P
requirements of the following European
Community Directives: 89/336/EEC
(Electromagnetic Compatibility) and 73/23/EEC
(Low Voltage) as amended by 93/68/EEC (CE
Marking). However, electrical noise or intense
electromagnetic fields in the vicinity of the
equipment may disturb the measurement
circuit. Measuring instruments will also respond
to unwanted signals that may be present within
the measurement circuit. Users should exercise
care and take appropriate precautions to avoid
misleading results when making measurements
in the presence of electronic interference.
Electrical Specifications
Accuracy at 23 °C ± 5 °C, <75 % RH, guaranteed
for one year.

DC Volts

Ranges: 1000 mV, 10 V, 100 V, 1500 V
Resolution: 0.1 mV in 1000 mV range:
Accuracy: ±(0.1 % rdg + 5 dgt)
Input Impedance: 10 MΩ
CMRR: >120 dB up to 1500 V dc
NMRR: >60 dB at 50 or 60 Hz
OL Protection: 1500 V dc or 1000 V ac rms.
Transient protection: 12 kV impulse (1.2
µS/50 µS) based on EN 61010-1:2001 impulse
requirement for at CAT IV 1000 V/1500V dc
product. This product should not be used in
installations where transients exceed 12 kV.

AC Volts True rms

Ranges: 1000 mV, 10 V, 100 V, 1000 V
Resolution: 0.1 mV in 1000 mV range
Accuracy:
1000 mV (45 Hz to 400 Hz)
±(1.2 % rdg + 10 dgt)
10 V, 100 V (45 Hz to 500 Hz)
±(1.2 % rdg + 10 dgt)
10 V, 100 V (500 Hz to 2 kHz)
±(2.0 % rdg + 10 dgt)
1000 V (45 Hz to 1 kHz)
±(2.0 % rdg + 10 dgt)
Input Impedance: 10 MΩ
Conversion type: True rms, ac coupled 5 % to
100 % of range
Crest factor: ≤ 3
OL Protection: 1500 V dc or 1000 V ac rms
Transient protection: 12 kV impulse (1.2
µS/50 µS) based on EN 61010-1:2001 impulse
requirement for at CAT IV 1000 V product. This
product should not be used in installations
where transients exceed 12 kV
12