Product Maintenance

Cleaning
To clean the meter, use a soft cloth moistened with water. Using benzene, alcohol,
acetone, ether, paint thinner, lacquer thinner, ketone or other solvents may deform
or discolor the meter and its display.
Troubleshooting
If the meter appears to operate improperly, check the following items first.
1. Review the operating instructions to ensure the meter is being used properly.
2. Inspect and test the continuity of the test leads.
3. Make sure the battery is in good condition. The low battery symbol B appears
when the battery falls below the level where accuracy is guaranteed. Replace a
low-battery immediately.
4. Check the condition of the fuses if the current ranges operate incorrectly.
To avoid electrical shock remove the test leads from both the
meter and the test circuit before accessing the battery or the
fuses.

Battery and Fuse Replacement

To access these parts, you must first remove the cover from the battery
compartment. The battery cover is on the rear of the meter and is held in place with
two screws. After removing these screws, you can easily remove and replace the
battery. To replace the mA fuse, pry it from its clips using a small screwdriver. A
spare mA fuse is located between the battery and the mA fuse.
Battery:
To replace the 10 A fuse, remove the battery, remove the four rear-case screws,
separate the case, remove the 10 A fuse cover, and remove and replace the 10 A
fuse. Re-install the fuse cover.
10 A Fuse: Fast Blow 10 A/600 V, minimum interrupt rating 30 kA (10 x 38 mm)

Repair

All test tools returned for warranty or non-warranty repair or for calibration should
be accompanied by the following: your name, company's name, address, telephone
number, and proof of purchase. Additionally, please include a brief description of
the problem or the service requested and include the test leads with the meter.
Non-warranty repair or replacement charges should be remitted in the form of a
check, a money order, credit card with expiration date, or a purchase order made
payable to Amprobe
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting
repair. During the warranty period any defective test tool can be returned to your
Amprobe
Please check the "Where to Buy" section on
distributors near you. Additionally, in the United States and Canada In-Warranty
repair and replacement units can also be sent to a Amprobe
Center (see below for address).
0.561.8187
9 V NEDA
mA Fuse: Fast Blow 250 mA/600 V (Amprobe
fuse (Amprobe
Test Tools.
®
Test Tools distributor for an exchange for the same or like product.
®
www.
XWWARNING
FP160) or equivalent.
®
www.amprobe.com
5
.com
See Figure
-10-
®
for a list of
Test Tools Service
®
information@itm.
FP375)