1 Overview
1.1 Front panel
1 Control panel for receiver unit 1
2 Control panel for receiver unit 2
3 Power switch
4 Reception antennas
5 Volume controls, one each for receiver unit 1
and receiver unit 2
6 Keys "Up"  and "Down" 
– to select the transmission channel, sepa-
rately for both receiver units
1 . In the respective control panel, press the
key  or  (for a minimum of 1 s): on the
display, RX1 or RX2 (b) starts flashing .
2 . As long as the indication keeps flashing
(for approx . 3 s after pressing a key), the
channel can be selected: With the key  ,
the channels are scanned in ascending
order; with the key , they are scanned
in descending order .
– to activate / deactivate the lock mode for
both receiver units together
1 . To activate the lock mode, in one of the
control panels, keep the keys  and 
pressed simultaneously until LOCK (a)
is displayed: The transmission channels
cannot be changed any more .
2 . To deactivate the lock mode, in one of
the control panels, keep the keys  and
 pressed simultaneously until LOCK dis-
appears .
7 Multifunction LC display
– for both receiver units:
a indication LOCK with activated lock
mode: in the lock mode, it is no longer
possible to change the transmission
channels adjusted for the two receiver
units
– for receiver unit 1 and receiver unit 2 re-
spectively:
b indication RX1 (for receiver unit 1) or RX2
(for receiver unit 2): starts flashing when
the channel adjusting mode has been
activated for the respective receiver unit
6
TXS-895
CHANNEL 1
CHANNEL 1
MIN.
MAX.
5
6
c bar graph RF for the strength of the
c
d
e
B
d bar graph AF for the volume of the audio
f
e reception indication
f indication of the transmission channel
g muting symbol: indicates that the re-

1.2 Rear panel

8 Output for the mixed signal of the two re-
ceiver units (6 .3 mm jack, unbal .) for con-
nection to a line input of a mixer / amplifier
9 Power supply jack for connection of the
power supply unit provided
10 BNC jacks for connection of the antennas
(4) provided
11 Balanced XLR outputs, for the output signal
from the receiver unit 1 (CH 1) and the out-
put signal from the receiver unit 2 (CH 2),
for connection to two balanced microphone
inputs of a mixer / amplifier
12 Squelch controls, for receiver unit 1 (CHAN-
NEL 1) and receiver unit 2 (CHANNEL 2), to
adjust the muting threshold

2 Safety Notes

The units (receiver and the power supply unit)
correspond to all relevant directives of the EU
and are therefore marked with
WARNING The power supply unit uses danger-
The units are suitable for indoor use only . Pro-
tect them against dripping water and splash
water, high air humidity and heat (admissible
ambient temperature range 0 – 40 °C) .
Immediately disconnect the power supply unit
from the mains socket
1 . if the units are visibly damaged,
2 . if a defect might have occurred after a unit
was dropped or suffered a similar accident,
3 . if malfunctions occur .
In any case the units must be repaired by skilled
personnel .
For cleaning only use a dry, soft cloth; never
use chemicals or water .
No guarantee claims for the units or liability
for any resulting personal damage or material
damage will be accepted if the units are used
for other purposes than originally intended, if
1
RF
AF
A
B
HOLD
A
B
RX1
RX2
CH
CH
7
radio signal received: the more segments
are displayed, the better the reception
signal received [independent of the vol-
ume controls (5)]: the more segments are
displayed, the higher the volume level
or
: indicates
A
B
which of the two antennas receives the
radio signal of higher strength
spective receiver unit has been muted
because it receives either a radio signal
which is too poor or no radio signal at all
.
ous mains voltage . Leave servicing
to skilled personnel only . Inexpert
handling of the unit may result in
electric shock .
2
CHANNEL 2
CHANNEL 2
MIN.
MAX.
6
5
they are not correctly connected or operated
or if they are not repaired in an expert way .
If the units are to be put out of oper-
ation definitely, dispose of the units in
accordance with local regulations .

3 Applications

In combination with two transmitters of the
TXS-895 series from IMG STAGELINE, the 2-chan-
nel multifrequency receiver TXS-895 makes up
a wireless audio transmission system which is
ideally suited for musicians and live performance
on stage . The transmission range depends on
local conditions; a maximum range of 100 m may
be reached . For audio transmission, 16 channels
are available, to be freely selected in the UHF
frequency range of 518 – 542 MHz .
Both receiver units use the "diversity" tech-
nology: The transmission signal is received by two
antennas placed at a distance from each other
and checked for its quality . The signal with the
highest signal quality will be used .

3.1 Conformity and approval

Herewith, MONACOR INTERNATIONAL declare
that the product TXS-895 complies with the di-
rective 2014 / 53 / EU . The EU declaration of con-
formity is available on the Internet:
www .img-stageline .com
Restrictions or requirements apply in the fol-
lowing countries:
CZ
IT
The regulations of the country where the product
is operated must always be observed . Prior to
operating the product, please contact the MONA-
COR subsidiary or the corresponding authorities
of the respective country . Links to the national
authorities can be found via the following Inter-
net address:
www .cept .org
t ECC
t Topics
t Other spectrum topics: SRD Regulations and
indicative list of equipment sub-classes
t EFIS and National Frequency Tables

4 Rack Installation

The receiver is designed as a table top unit or
for installation into a rack for units of a width of
482 mm (19") . For rack installation, unscrew the
four feet, then screw the two supplied mounting
brackets with two screws each to the front at the
left and right sides of the housing .
3