Lock Mode - IMG STAGELINE TXS-895 Mode D'emploi

Récepteur 2 canaux pour microphones sans fil
Masquer les pouces Voir aussi pour TXS-895:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ANT. 2
CH.2
10
11
5 Connection
1) Insert the two antennas (4) provided into the
BNC jacks ANT 1 and ANT 2 (10) and put them
in a vertical position .
Hint: The pair of signal amplifiers TXS-875B (availa-
ble as an accessory) can be used to increase the trans-
mission range and the interference resistance . The
antenna jacks of the receiver supply the amplifiers
with power .
2) For connection to the subsequent unit (e . g .
mixer, amplifier), the following audio outputs
can be used:
– bal . XLR outputs CH 1 and CH 2 (11) for
the  output signals of the individual re-
ceiver units, for connection to a balanced
microphone input
– unbal . 6 .3 mm jack MIXED OUT (8) for the
mixed signal of the two receiver units, for
connection to a line input (a matching con-
nection cable is provided)
3) Connect the power supply unit provided to the
power supply jack 12 V ⎓ (9) and to a mains
socket (230 V/ 50 Hz) .
6 Operation
Switch on the receiver with the switch POWER
(3) . The display (7) shows the channel indications
(f) of the transmission channels adjusted for the
two receiver units . As long as a receiver unit does
not receive a radio signal of sufficient strength, it
is muted [symbol
(g) is displayed] .
Make the following adjustments separately for
each receiver unit .
1) Switch on the transmitter . If the channel in-
dication (f) displays a different channel than
the one adjusted on the transmitter, adjust the
receiver unit to the channel of the transmitter:
chapter 6 .1 .
If the transmitter and the receiver unit
have been adjusted to the same transmission
channel and if the strength of the radio signal
received is sufficient, muting is deactivated
[symbol
(g) disappears] . One of the indica-
tions
or
(e) lights up to indicate which of
A
B
the two antennas receives the radio signal of
higher strength . The bar graph RF (c) indicates
the reception quality: the more segments are
displayed, the better the reception .
If the reception is poor or disturbed, please
check if
– the reception can be improved by using a
different transmission channel .
– the batteries of the transmitter are not suffi-
ciently charged any more (see battery status
indication on the transmitter) .
– the distance between the transmitter and
the receiver is too long .
– the reception is disturbed by objects in the
transmission path .
– the reception can be improved by turning
the antennas .
8
CH. 1
CHANNEL 2
MIXED OUT
SQUELCH
UNBALANCED
12
– the squelch adjusted with the control
SQUELCH (12) is too high (
2) Switch on the subsequent audio unit or ad-
vance the corresponding control on the mixer .
3) Speak / sing into the microphone and use the
the volume control (5) to match the output
level of the receiver unit to the input of the
subsequent unit .
The bar graph AF (d) on the display shows
the volume of the audio signal received: the
more segments are displayed, the higher the
volume level . Adjust the optimum volume on
the transmitter (
transmitter) .
4) Use the control SQUELCH (12) – CHANNEL 1 for
receiver unit 1, CHANNEL 2 for receiver unit 2 –
to define the threshold value for the squelch .
The further the control is turned clockwise,
the higher the threshold value .
The squelch will mute the receiver unit,
if, during music intervals, high-frequency in-
terference signals are received whose levels
are below the threshold value adjusted . With
a higher threshold value, however, the trans-
mission range will be reduced as the receiver
unit will also be muted if the strength of the
radio signal of the transmitter falls below
the threshold value adjusted . Thus, a higher
threshold value may be adjusted if the recep-
tion is good . However, with a longer distance
between the transmitter and the receiver, a
lower value should be selected .
After operation, switch off the receiver with the
switch POWER (3) . If the receiver is not used for
a longer period of time, disconnect the power
supply unit from the mains socket as it will still
consume some power when the receiver has
been switched off .
6.1 Adjusting the transmission channel
1) In the control panel of the receiver unit, press
the key  or  (6) [for a minimum of 1 s] . On
the display, the indication (b) for the channel
adjusting mode starts flashing: RX1 (for receiver
unit 1) or RX2 (for receiver unit 2) .
2) As long as the indication keeps flashing, the
channel can be selected: With the key  , the
channels are scanned in ascending order;
with the key , they are scanned in descend-
ing order . The 16 channels are assigned to the
following receiving frequencies:
Channel
Frequency
1
518 .750 MHz
2
519 .375 MHz
3
521 .125 MHz
4
522 .000 MHz
5
523 .250 MHz
6
524 .250 MHz
7
524 .875 MHz
8
526 .000 MHz
3) Approx . 3 seconds after the last actuation of
a key, the indication RX1 or RX2 will disap-
9
CHANNEL1
12 V
SQUELCH
step 4) .
Note: It is not possible to set both receiver units to
the same channel . The channel selected for the first
receiver unit will be automatically skipped during chan-
nel adjustment for the second receiver unit .

6.1.1 Lock mode

To prevent accidental change of the transmission
channels selected, it is possible to activate the
lock mode . With the lock mode activated, it is not
possible to call up the channel adjusting mode
instruction manual of the
for any of the two receiver units .
1) To activate the lock mode, in one of the control
2) To deactivate the lock mode, in one of the
Note: The lock mode is automatically deactivated each
time the unit is switched on .
7 Specifications
Type of unit: � � � � � � � � � � PLL multifrequency receiver
Radio frequency range: � � 518 – 542 MHz,
Audio frequency range: � � 40 – 18 000 Hz
THD: � � � � � � � � � � � � � � � � < 0�6 %
Dynamic range: � � � � � � � � > 105 dB
Interference suppression: � pilot tone and
Audio outputs
Ambient temperature: � � � 0 – 40 °C
Power supply: � � � � � � � � � via the power supply unit
Dimensions (W × H × D): � 420 × 55 × 230 mm
Weight: � � � � � � � � � � � � � � 2�1 kg
Subject to technical modification .
Channel
Frequency
9
526 .875 MHz
10
528 .250 MHz
11
531 .250 MHz
12
532 .000 MHz
13
533 .625 MHz
14
534 .750 MHz
15
536 .250 MHz
16
541 .750 MHz
All rights reserved by MONACOR
& Co. KG. No part of this instruction manual may be repro-
duced in any form or by any means for any commercial use.
pear and the receiver unit will exit the channel
adjusting mode .
(locking the channel selector keys)
panels, keep the keys  and  pressed simul-
taneously until LOCK (a) is displayed .
control panels, keep the keys  and  pressed
simultaneously until LOCK disappears .
in diversity technology
divided into 16 channels
(
table, chapter 6�1)
noise squelch
2 × XLR: � � � � � � � � � � � � 150 mV/150 Ω (bal�)
1 × 6�3 mm jack: � � � � � 500 mV/1 kΩ (unbal�)
provided and connected to
230 V / 50 Hz
(w /o antennas)
INTERNATIONAL GmbH
®
ANT. 1
10
7