9.4 Fuse replacement

Before opening the BENNING MM 9/ 10 make sure that it is
free of voltage! Electrical danger!
The BENNING MM 9/ 10 is protected against overload conditions by means of
a fitted fuse (G melt insert) 10 A (see Figure 12)
Proceed as follows to replace the fuse:
-
Disconnect the safety measuring leads from the measuring circuit.
-
Disconnect the safety measuring leads from the BENNING MM 9/10/.
-
Turn the rotary switch  to the switch setting "OFF".
-
Remove the rubber protection frame  from the BENNING MM 9/ 10.
-
Lay the BENNING MM 9/ 10 face down and release the four slot screws of
the housing bottom.
Do not undo any screws on the printed circuit of the
BENNING MM 9/ 10!
-
Lift up the housing bottom in the lower section and remove the same at the
top from the front section.
-
Lift one end of the defective fuse from the fuse holder.
-
Fully push the defective fuse out of the fuse holder.
-
Insert a new fuse which has the same current rating, disconnecting charac-
teristic and dimensions.
-
Make sure that the new fuse is seated centred in the holder.
-
Order the battery supply lines such that they are not crushed between the
housing parts.
-
Engage the front end on the housing bottom and fit the three screws.
-
Insert the BENNING MM 9/ 10 into the rubber protection frame  .
see figure 12:
9.5 Calibration
To maintain the specified accuracy of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the appliance to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt

9.6 Spare parts

Fuse F 10 A, 500 V, 1.5 kA, D = 6.3 mm, L = 32 mm
10. Application of rubber protection frame
-
You can store the safety measuring leads by winding the safety measuring
leads around the rubber protection frame  and engaging the tips of the
safety measuring leads with protection against the rubber protection frame
 (see figure 13).
-
You can engage a safety measuring lead to the rubber protection frame
 , that the measuring tip protrudes freely, in order to be able to apply the
measuring tip - jointly with the BENNING MM 9/ 10 to a measuring point.
-
The rear support on the rubber protection frame  provides for an inclined
setup of the BENNING MM 9/ 10 (facilitates reading) or attachment (see
Figure 14).
The rubber protection frame  is fitted with a lug which can be freely used
for an attachment option.
see figure 13:
see figure 14:
11. Technical data of the measuring accessories
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protective class II (  ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Only use the measuring leads if in perfect and clean condition as well as
according to this manual, since the protection provided could otherwise be
09/ 2013
Fuse replacement
Winding up of the safety measurement leads
Erecting the BENNING MM 9/ 10
BENNING MM 9/ 10
part no. 749726