Operating instructions and warnings
Channel selection and linking on the transmitter
The built-in receiver can control both the start input and the pedestrian one. By setting the correct value
of the parameter "P009 Selection and linking of radio channels" it is possible to decide which button of
the transmitter will activate each input. If you check on the "working parameters" table you will realize
that the P009 parameter allows you to choose among 16 different combinations. If, for instance, you
attribute value "3" to the parameter P009, all memorized transmitters will activate the start input throu-
gh the CH1 and the pedestrian input through CH4. Please see chapter "8.4 Personalization of working
parameters" in order to select the right combination.
8.4
Personalization of working parameters
Instructions
The control board is ready to receive instructions
Scroll down the parameters until you visualize the one you wish to set (ex. P010)
Confirm! The display shows the set parameter value
Increase or decrease the value until you reach the value you wish to define
Confirm! The display shows again the parameter
Scroll down the parameters until you visualise "----". The control board awaits
further instructions
The operator is now ready to work according to the new working parameters.
8.5
Resetting of default parameters (p.007)
DEA 203RR control board software includes a reset procedure to restore default values (the one set by
the maker) of all settable parameters, see Table 2 Parameters. The value originally set for each parameter
is shown in the "working parameters table". In case you should reset all values and restore all default
values, proceed as follows:
Instructions
The control board is ready to receive instructions
Scroll down the parameters until you visualize P007
Confirm! The control board awaits a further confirmation
Confirm by pressing on the OK button. The procedure starts
All parameters are now set at their original value
Scroll down the parameters until you visualise "----". The control board awaits
further instructions
8.6
Safety devices
DEA 203RR control board allows installers to set up installations that truly comply with European regu-
lations concerning garage doors and gates operators. More specifically, this control board allows you to
comply with the limits set by the same regulations as to impact forces in case of collision with obstacles.
DEA 203RR control board is equipped with a built-in anti-crush safety device that, associated to the
18
possibility of tuning up the motor speed, allows you to comply with the limits imposed by the above men-
tioned regulations in most installations.
In particular, you can adjust the anti-crush safety device sensitivity by properly setting the value assi-
gned to the following parameters
•P014motor force in opening: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
•P015motor force in closing: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
In case the gate structural features do not allow you to comply with the above force limits, it is possible
to use external safety devices inputs (terminal no. 12). "CST" input can be configured by setting properly
parameter no. 18:
•P018 = 0"safety rib" mode functioning: when the input is activated, it reverses the movement direction
•P018 = 1"photoelectric barrier" mode functioning: when the input is activated, it stops the movement
R
Function
Function
(see also "8.4 Personalization of working parameters "):
Display
Display