Personalization Of Working Parameters; Reset Of Default Parameters (P.007); Safety Devices - Dea 124RR Notice D'emploi Et Avertissements

Armoire de commande programmable
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Operating instructions and warnings
Channel selection and linking on the transmitter
The built-in receiver can control both the start input and the pedestrian one. By setting the correct value
of the parameter "P009 Selection and linking of channels" it is possible to decide which key of the tran-
smitter will activate each input.
If you check on the "working parameters" table you will realize that the P009 parameter allows you to
choose among 16 different combinations. If, for instance, you attribute value "3" to the parameter P009,
all memorized transmitters will activate the start input through the CH1 and the pedestrian input through
CH4. Please refer to chapter "8.4 Personalization of working parameters" in order to select your own
combination.
8.4

Personalization of working parameters

Instructions
The control board is ready to receive instructions
Scroll down the parameters until you visualize the one you wish to set (ex. P010)
Confirm! The display shows the set parameter value
Increase or decrease the value until you reach the value you wish to define
Confirm! The display shows again the parameter
Scroll down the parameters until you visualise "----". The control board awaits
further instructions
The automation is now ready to work according to the new working parameters.
8.5
Resetting of default parameters (p.007)
DEA 124RR control board software includes a reset procedure to restore default values (the one set by
the maker) of all settable parameters. The value originally set for each parameter is shown in the "working
parameters table". In case you should reset all values and restore all default values, proceed as follows:
Instructions
The control board is ready to receive instructions
Scroll down the parameters until you visualize P007
Confirm! The control board awaits a further confirmation
Confirm by pressing on the OK button. The procedure starts
All parameters are now set at their original value
Scroll down the parameters until you visualise "----". The control board awaits
further instructions
8.6

Safety devices

DEA 124RR control board allows fitters to set up installations that truly comply with European regula-
tions concerning automated garage doors and gates. More specifically, this control board allows you to
comply with the limits set by the same regulations as to impact forces in case of collision with obstacles.
20
DEA 124RR control board is equipped with a built-in anti-crush safety device that, associated to the
possibility of tuning up the motors' speed, allows you to comply with the limits imposed by the above
mentioned regulations in most installations.
In particular, you can adjust the anti-crush safety device sensitivity by properly setting the value assi-
gned to the following parameters (see also "8.4 Personalization of working parameters "):
•P014 motor 1 force in opening: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
•P015 motor 1 force in closing: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
In case the gate structural features do not allow you to comply with the above force limits, it is possible
to use external safety devices inputs (terminal no. 12). SIC inputs can be configured by properly setting
parameter no. 18:
•P018= 0 "rib" mode functioning: when the input is activated the movement direction of the motors is inverted.
•P018=1"photoelectric barriers" mode functioning: when the input is activated, the motor stops.
Function
Function
Display
Display

Publicité

Table des Matières
loading