WARNING To ensure an appropriate level of electrical safety always keep very low tension cables
(motors power supply, controls, electric lock, aerial and auxiliary circuits power supply) apart from (min
4 mm if not insulated, 1 mm through insulation) 230V power supply cables. To keep them apart put
cables inside a tubing tray and fasten them with clamps near the terminal board. Make sure cables are
not damaged or worn off during installation.
WARNING Any installation, maintenance or repair operation on the whole system must be carried out
exclusively by qualified personnel. All these operations must be performed only after disconnecting the
power supply, and operating in strict compliance with the electrical standards and regulations in force
locally.
WARNING See the user's manual of the operator by DEA System you are working on for further in-
structions on assembling and control board wiring operations (such as drilling holes to allow for wire
passage, cable clamps use, ect). Failure to comply with these instructions may jeopardize the level of
electrical safety.
WARNING During the motors stroke memorization, the control board detects automatically the presen-
ce and type of photocells, safety devices and limit switches which are installed. It is therefore essential
that during this phase the latter be properly connected and working.
WARNING
Wrong assessment of impact forces may cause serious damage to people, animal and
things. DEA System reminds all personnel that the installer must ascertain that these impact forces,
measured according to EN 12245 prescriptions, are actually below the limits indicated by EN12453
regulation.
WARNING Any external safety device installed in order to conform to the limits set for impact forces
must comply with EN12978.
WARNING Using spare parts not indicated by DEA System and/or incorrect re-assembly may endanger
people, animals and property, and may also cause malfunctioning of the product: always use parts
provided by DEA System and follow assembly instructions
WARNING Disposal of packaging materials (such as plastic, card board, etc.) must be done according
to regulations in force locally. Do not leave plastic bags and polystyrene within the reach of children
3 MODELS AND CONTENTS OF THE PACKAGE
The control board 203RR can be supplied together with DEA System gate operators for counterweight
overhead doors, sliding doors and barriers, or they are supplied individually as spare part to be used only
with DEA System above mentioned gate operators.
4 PRODUCT DESCRIPTION
203RR control board has been designed for the control of DEA System 230V gate operators with
built-in magnetic encoder. It can therefore be used to automate counterweight overhead doors, sliding
doors and barriers. It is extremely versatile, easy to install and fully complies with European regulations
concerning electromagnetic compatibility and electric safety
Main features of the product:
1. setting all parameters by 3 keys and a 4-digit display;
2. possibility of fine tuning of motor speed both during its complete stroke and during the last phase of it
(slow-down). It preserves motor torque even at very low speed;
3. encoder-controlled positioning system (only end of stroke or stop while closing are needed)
4. possibility to set at will the slow-down duration
5. Internal anti-crash safety device whose sensitivity can be adjusted (according to a 70-level scale) se-
parately for both operating directions;
6. inputs to connect both normal and powered external safety devices (mechanical ribs or photocell bar-
riers), with the possibility to run a self-test before each operation. Controlled photocells;
7. built-in 433,92MHz radio receiver for both HCS and HT12E coding offering the possibility to search
and delete each transmitter separately.
Operating instructions and warnings
A4
A5
A6
A7
A8
A9
A10
13
2 0 3 R R
R