Scott Safety Promask Instructions D'utilisation page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
3. Selection
2
Promask/Promask
Breathing protector equipped with filter
Type of protective device
Full face mask with particle filter P3
Full face mask with gas filter *)
Device with combined filter
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not exceeded. For
non-powered filtering devices with gas filter, concentration must not exceed 0.1 vol.% in gas filter class 1 and 0.5
vol.% in gas filter class 2 and 1.0 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
Note!
In Australia only, the following limitations apply:
Provides P3 protection only with a full face respirator (AS/ NZS 1716:2012 refers).
Provides P2 protection with a half face respirator negative pressure respirator
Promask + blower device
Blower-assisted breathing protector equipped with filter
Type of protective device
Power-assisted full face mask with
particle filter TM3P
Power-assisted full face mask with
gas filter *)
TM3 gas filter class 1, 2 or 3
Device with combined filter
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not exceeded. For
power-assisted filtering devices with gas filter, concentration must not exceed 0.05 vol.% in gas filter class 1 and
0.1 vol.% in gas filter class 2 and 0.5 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
4. Use, and Donning
See Instructions for Use of the filter and blower device to be used.
Check before use
intactness of facepiece, rubber parts and visor
head harness condition and elasticity
that speech diaphragm is in place
that exhalation valve is in place and that its cover is properly fastened
that inh. and exh. valves function properly
that the filter is correct for the intended use (filter type and class)
that storage period of the filter has not been exceeded
filter condition and intactness. Shake the filter to ensure that there are no loose
components/contents. The filter shall be replaced if it has been exposed to strong press or
impact. It may be damaged, also by a fall on a hard surface, also when attached to a mask /
blower device.
With a blower device
Check adequate air flow (see Instructions for Use of the blower unit).
+ filter
Multiples of threshold concentration **)
APF (Assigned protection factor)
BS 4275 (GB)
40
20
The specified multiples of threshold value for the gas or particle filters
are given separately, but in all cases the lowest value applies
Multiples of threshold concentration **)
APF (Assigned protection factor)
BS 4275 (GB)
40
40
The specified multiples of threshold value for the gas or particle filters
are given separately, but in all cases the lowest value applies.
21
BGR 190-ZH1/701 (DE)
400
Particles
400
Filter types A, B, E, K, AX, SX, Hg-P3 and NO-
P3 have different applications. For more
information, see Instructions for Use of Scott
Safety filters.
BGR 190-ZH1/701 (DE)
500
For devices with combined filter apply the
relevant limitations of gas and particle filters.
500
Remarks, limitations
Remarks, limitations