Safety Instructions; Conformity With Standards; Field Of Application - CEAG GHG 522 44 Mode D'emploi

Fiches et prises de 32 a
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dimensions in mm
X = fixing dimensions
Inlet, 3-pole
Inlet, 3-pole
Inlet, 3-pole
Inlet, 3-pole
Inlet, 3-pole
Inlet, 4-pole
Inlet, 4-pole
Inlet, 4-pole
Inlet, 4-pole
Inlet, 4-pole
Drilling template for flange sockets
Drilling template for inlets
Fig. 1
Fig. 2
Item 2
Item 1
Fig. 3
Item 3
Item 1
Item 2
Plug and socket system 32A, GHG 522
2

Safety instructions

The GHG 522 plugs and sockets
are not suitable for explosion
hazardous areas.
Modifications to the plugs and sockets or
changes of their design are not permitted.
They shall be used for their intended
purpose and in perfect and clean condition.
For replacement and repair only genuine
Cooper Crouse-Hinds (CCH) spare parts shall
be used.
Repairs that affect the explosion protection,
may only be carried out by CCH or a qualified
electrician in compliance with the respective
national regulations.
Prior to taking the plugs and sockets into
operation, they will have to be checked in acc.
with the instruction as per section 6.
The sockets may only be used in
undamaged condition.
Before the initial operation, any foreign
matter will have to be removed from the
the plugs and sockets.
Observe the national safety rules and
regulations for prevention of accidents as
well as the safety instructions included in
these operating instructions and set in
italics the same as this text!
3

Conformity with standards

The apparat is conform to the standards
specified in the EC-Declaration of conformity.
It has been designed, manufactured and
tested according to the state of the art and to
DIN EN ISO 9001.
The apparats fulfil further requirements, such
as the EC directive on electromagnetic
compatibility (2004/108/EEC)
4

Field of application

The plugs and sockets GHG 522 are suitable for
use in heavy industrial areas acc to. IEC 309!
Item 2
The enclosure materials employed, including the
exterior metal parts, are made of high-quality
materials which ensure a corrosion protection and
resistance to chemical substances corresponding
to the requirements in a "normal industrial
atmosphere":
- impact resistant polyamide
- glass-fibre reinforced polyester
- special steel AISI 316 L
The apparat is conform to the standards
specified in the EC-Declaration of conformity.
It has been designed, manufactured and
tested according to the state of the art and to
DIN EN ISO 9001.
5
Use/Properties
The GHG 522 plugs and sockets are used for
the power supply of local controls with varying
locations, as well as of electrical installations,
mobile machinery and driving gear in
industrial areas.
Acc. to IEC they are used up to max. 32A (see
page 7, Technical data).
The plugs and sockets can generally be used
for the voltage range laid down in IEC 309
(e.g. U
400V that corresponds to the voltage
N
range 380-415V).
The apparatus connected to the plug shall
be suitable for the applied mains voltage.
Fig. 1: In order to activate the socket, first the
bayonet ring item 2 is to be screwed off the
socket item 1 and to be folded open.
Fig. 2: After pushing the plug into the socket,
Fig. 2:
Fig. 2:
Fig. 2:
Fig. 2:
the bayonet ring of the plug item 2 is screwed
to its stop onto the socket in order to
establish IP 66 protection category.
For operating the 4-pole wall socket (with
interlocking switch) proceed as follows:
Fig. 1 + fig. 2
Fig. 1 + fig. 2, as described above.
Fig. 1 + fig. 2
Fig. 1 + fig. 2
Fig. 1 + fig. 2
Fig. 3: The switch item 3 is switched on,
Fig. 3:
Fig. 3:
Fig. 3:
Fig. 3:
thereby locking the plug in the socket.
After switching on the socket, the bayonet
ring item 2 of the plug is screwed to its stop
onto the socket item 1 in order to maintain the
protection category acc. to the type label also
whilst the plug is inserted.
Proceed in inverse order to switch off and pull
the plug from the wall socket with switch.
After having removed the plug from the
socket, close the latter with the folding cover
and secure it with the bayonet ring in order to
establish IP 66 type of protection.
The plug can be pushed into the socket
The plug can be pushed into the socket
The plug can be pushed into the socket
The plug can be pushed into the socket
The plug can be pushed into the socket
and pulled out of it only whilst the wall
and pulled out of it only whilst the wall
and pulled out of it only whilst the wall
and pulled out of it only whilst the wall
and pulled out of it only whilst the wall
socket with switch is switched off. f. f. f. f.
socket with switch is switched of
socket with switch is switched of
socket with switch is switched of
socket with switch is switched of
The user alone is responsible for the
appropriate use of this plug and socket
system.
After a short in the circuit, the
operativeness has to be checked.
The data as per point 3 and 4 will have to
be taken into account with the use.
Applications other than described are not
permitted without CCH's prior written
consent.
Cooper Crouse-Hinds GmbH