Fiches et prises de 63a, à 4 pôles et 5 pôles, pour utilisation industrielle
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Steckvorrichtungen für Industriean-
wendungen
63A, 4-polig und 5-polig,
GHG 524
Plug and socket system for
industrial use
63A, 4-pole and 5pole,
GHG 524
Fiches et prises de 63A, à 4 pôles et
5 pôles, pour utilisation industrielle,
GHG 524
GHG 510 7003 P0003 D/E/F (D)
COOPER Crouse-Hinds GmbH
COOPER Crouse-Hinds GmbH
COOPER Crouse-Hinds GmbH
COOPER Crouse-Hinds GmbH
COOPER Crouse-Hinds GmbH
Neuer Weg - Nord 49
D 69412 Eberbach / Germany
Fone
+49 (0) 6271/806 - 500
Fax
+49 (0) 6271/806 - 476
Internet: http://www.CEAG.de
E-Mail: Info-ex @ ceag.de
GHG 524 44
Betriebsanleitung
Operating instructions
Mode d'emploi
GHG 524 74

Publicité

Table des Matières
loading

Sommaire des Matières pour CEAG GHG 524 44

  • Page 1 63A, 4-polig und 5-polig, GHG 524 Plug and socket system for industrial use 63A, 4-pole and 5pole, GHG 524 44 GHG 524 Fiches et prises de 63A, à 4 pôles et GHG 524 74 5 pôles, pour utilisation industrielle, GHG 524...
  • Page 2: Table Des Matières

    Steckvorrichtung 63A, Plug and socket system 63A, Fiches et prises de 63A, GHG 524 GHG 524 GHG 524 Inhalt: Inhalt: Inhalt: Inhalt: Inhalt: Contents: Contents: Contents: Contents: Contents: Contenu: Contenu: Contenu: Contenu: Contenu: Inhalt........Contents......Contenu......Maßbild....... Dimensional drawings..Plans cotés......11-12 Anschlussbild......
  • Page 3: Maßbild

    Steckvorrichtung 63 A, GHG 524 Technische Angaben Maßangaben in mm X = Befestigungsmaße Steckvorrichtung GHG 524 Steckvorrichtung GHG 524 Steckvorrichtung GHG 524 Steckvorrichtung GHG 524 Steckvorrichtung GHG 524 Nennspannung: bis 690 V, 50/60 Hz Max. Nennstrom: Max. Vorsicherung: ohne therm. Schutz Schaltvermögen: 415V 500V...
  • Page 4: Sicherheitshinweise

    Flanschausschnitt Gerätestecker Als Ersatz und zur Reparatur dürfen nur Spannungsbereich 380 - 415V). Originalteile von CEAG verwendet werden. Reparaturen dürfen nur von CEAG oder Das am Stecker angeschlossene Betriebs- Bild 1 einer qualifizierten Elektrofachkraft in mittel muß für die anliegende Netzspan- Übereinstimmung mit national geltenden...
  • Page 5: Installation

    Steckvorrichtung 63A, GHG 524 Die Stecker sind im Freien vorzugsweise mit Der Zusammenbau erfolgt nach dem Bild 4 der Steckeröffnung (Stiftseite) nach unten Kabelanschluss in umgekehrter Reihenfolge. Pos 1 aufzubewahren bzw. mit optional erhältlichen Pos 2 Steckerschutzkappen zu verschließen. Der elektrische Anschluss der Gerätestek- ker erfolgt wie in Bild 6 bis 8 dargestellt: Pos 3 Pos 3...
  • Page 6: Anschlussbild

    / Änderungen wirkung anzuziehen. Danach sind die Schrauben Pos 4, der Zugentlastung Pos 3, Instandsetzungsarbeiten / Reparaturen dürfen fest anzuziehen. nur mit CEAG Originalersatzteilen vorgenom- 3-polig + N + PE men werden. Achtung! Übermäßiges Anziehen kann die Zugentlastungswirkung negativ beeinträch- Umbauten oder Änderungen am Betriebs-...
  • Page 7: Dimensional Drawings

    Plug and socket system 63A, GHG 524 Technical data Dimensions in mm X = fixing dimensions Plug and socket GHG 524 Plug and socket GHG 524 Plug and socket GHG 524 Plug and socket GHG 524 Plug and socket GHG 524 Rated voltage: up to 690 V, 50/60 Hz Rated current:...
  • Page 8: Safety Instructions

    (e.g. U 400V that corresponds to the voltage Repairs that affect the explosion protection, range 380-415V). may only be carried out by CEAG or a qualified Fig. 1 electrician in compliance with the respective The apparatus connected to the plug shall national regulations.
  • Page 9: Installation

    Plug and socket system 63A, GHG 524 In the open air, the plugs must be kept with The inlets are electrically connected as Fig. 4 the plug opening (pin side) pointing shown in fig. 6 thru 8. Item 1 downwards or be closed with protective plug Item 2 caps available as an optional extra (see Fig.
  • Page 10: Connection Diagram

    Mind! Overtightening might impair the pull- Repair/Overhaul/ relief effect! Modifications Repairs and overhaul may only be carried out with genuine CEAG spare parts. Closing the device Modifications to the device or changes of 3-pole + N + PE its design are not permitted.
  • Page 11: Plans Cotés

    Fiches et prises de 63A, GHG 524 Caracteristiques techniques Dimensions en mm X = dimensions de fixation Fiche et prise GHG 524 Fiche et prise GHG 524 Fiche et prise GHG 524 Fiche et prise GHG 524 Fiche et prise GHG 524 Tension nominale: jusqu’à...
  • Page 12: Consignes De Sécurité

    Des réparations qui portent sur la fourchette 380 - 415V). protection contre l’explosion, ne devront être exécutées que par CEAG ou par un L’ appareil connecté à la fiche doit être électricien qualifié en conformité avec la adapté à la tension du réseau règlementation nationale en vigueur.
  • Page 13: Installation

    Fiches et prises de 63A, GHG 524 En plein air, les fiches doivent être gardées avec Le raccordement électrique des Fig. 4 leur ouverture (côté des broches) vers le bas. A connecteurs se fait comme montré dans Pos 1 les figures 6 à 8: l’option, elles peuvent être fermées avec les Pos 2 capuchons protecteurs pour la fiche qui sont...
  • Page 14: Diagram De Connexion

    4, de la pince de décharge de qu’à l’aide de pièces de rechange d’origine traction, pos 3, doivent être serrées à fond. CEAG. 3-pôles + N + PE Attention! Un serrage excessif peut nuir à Il n’est pas permis de transformer ou de l’effet de décharge de traction.
  • Page 15: Konformitätserklärung

    GHG 524 ... Cooper Crouse-Hinds GmbH...
  • Page 16 +LQGV&($*  YHUWHJHQZRRUGLJLQJ Cooper Crouse-Hinds GmbH Cooper Crouse-Hinds GmbH Cooper Crouse-Hinds GmbH Cooper Crouse-Hinds GmbH Cooper Crouse-Hinds GmbH Neuer Weg - Nord 49 D 69412 Eberbach / Germany Fone: +49 (0) 6271/806-500 Fax: +49 (0) 6271/806-476 Internet: www.CEAG.de E-Mail: Info-ex@ceag.de...