Connection to the utilities (electrical connection)
The oven is supplied without power supply cable. The connection to the power network must be performed by interposing a
differential circuit breaker switch with suitable features, and minimum opening distance between the contacts of at least 3 mm.
To connect the oven to the electricity supply it is necessary to proceed as follows:
•
Remove the right side panel;
•
Connect the conductors of the power supply cable to the terminal board, which must be H07-RNF type-tested, with
conductors that have a suitable cross-section according to the regulations in force.
IN ADDITION, FOLLOW THESE INSTRUCTIONS:
•
The mains socket must be easily accessible and should not require moving the machine.
•
Electrical connection must be easily accessible even after the oven has been installed.
•
The distance between the oven and the socket must ensure that there is no tension in the supply cable. In addition, the
cable must not be at risk of getting under the base of the oven.
•
If the power cable is damaged, have it replaced by the technical assistance service or by a qualified service technician in
order to prevent any risk.
Grounding
It is mandatory for the system to be provided with an earthing system.
According to the regulations in force, it is mandatory to connect the equipment to an equipotential system whose efficiency
must be properly verified as prescribed by the rules in force.
The connection is made with the special clip at the rear of the oven, with a cable with a minimum section of 10mm
This clip is identified by the following symbol:
22
.