Optional Atmospheric Tank Installation
Tools and Installation Materials
3/8" Tubing
1" Plastic Piping
®
Teflon
Tape
Pipe Sealant
1 1/4" Threaded Male Adapter for Pump Inlet
1" Threaded Male Adapter for Pump Outlet
Plastic Pipe Cleaner
Plastic Pipe Cement
Plastic Pipe Cutter
Use both Teflon tape and pipe sealant on all threaded connections. It is not necessary to thread connections
to a complete stop. Leaving 2 -3 threads exposed will minimize the potential for fittings to crack. For plastic
connections, make sure fittings are first cleaned, then glued. For tubing connections, plastic tubing should be
cut straight with a sharp blade. These procedures will minimize leaks at the connections.
NOTE: If overflow is required, consult the technical service department.

Tank Connection

Refer to Figure 4 at right.
The figure at right shows the tank connection assembly.
Connect 3/8" tubing connector to 1/2" x 1" reducer
bushing.
Connect adaptor to outlet of 1" NPT tee.
To other outlet of tee, connect 1" short nipple.
Connect 1" 90º elbow to the 1" short nipple.
Connect 1" short nipple to 1" 90º elbow.
Connect nipple to 1" NPT check valve.
To common inlet of tee, connect 1" short nipple.
To nipple, connect 1" true union ball valve.
To other end of ball valve, connect 1" short nipple.
Disassemble the true union ball valve with the nipple.
Make the connection from this nipple to the tank.
Reassemble ball valve.
Add an overflow connection to the tank. Overflow should
be connected to an air gap prior to the drain.
High Level Control
Refer to Figure 5 at right.
Assemble the float switch components to the top of the tank.
Place the level control switch with the cord in the tank through the
manway.
Guide the cord out of the tank through the bulkhead, nipple, tee and
the cord grip.
Tighten in place.
Thread the HEPA filter horizontally onto the 3/8" nipple in the TEE.
Disconnect all power to the TX 1440 system.
Open the door on the front of the system.
Route the cord into the TX 1440 control box using another cord
grip.
Connect the wiring to the "System Float" terminals as shown on the
electrical wiring diagram (Figure 3 on page 13).
Kinetico Incorporated  Corporate Headquarters  Newbury, Ohio 44065  440-564-9111
Rev. 11/2016
Hepa Filter
To Pump
From RO
15
Level Control
Figure 4
Figure 5
Product No. 13591E