The TX RO is comprised of various components. A brief description has been provided for each of these
major components. The illustration helps depict the physical location of these components on the TX RO,
while the flow schematic shows the flow path through the system.
Inlet The inlet to the system is located adjacent
to the filter housing. This connection is 1/2" NPT.
The required inlet pressure is 15 psi at 3 gpm.
Feed Solenoid Valve
A nickel plated brass, normally closed (NC)
solenoid valve is used to shut flow off to the
system during shutdown or alarm conditions.
Pressure Gauge
This pressure gauge shows the water pressure
after it has been processed by the pump. It is
equal to the inlet pressure plus the pump
pressure.
Low Pressure Switch
The low pressure switch is used to shut the
system down if there is an inadequate feed
pressure. The set point for the pressure switch is
15 psi (1.0 bar). The switch is located between
the two housings.
Do not operate the system with this safety device
by-passed.
Pump-in-Tube The pump-in-tube provides
pressure to the TX RO as required for proper
operation. The use of this pump style is a design
advantage that also provides extraordinarily quiet
operation compared to typical pumps being used.
Typical operating pressure should be at 85 to 130
psi for the TX-ROs.
Membrane Housing / Membrane
Each membrane housing holds one 4" x 40"
(10.12cm x 101.16cm) Thin Film Composite
membrane.