Measuring Range; Error Listing; Specifications; Information - AMIX AFF16 Manuel Utilisateur

Masquer les pouces Voir aussi pour AFF16:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MEASURING RANGE

 With A weighted, Leq level range is from 60 to 120dB(A) (with CAP40A, CAP65 or CAP90A
sensor)
However, it is possible, as an option, to measure from 40 to 100dB(A) (with CAP40B or CAP90B
sensor)
 With C weighted, Leq level range is from 70 to 130dB(C) (with CAP40A, CAP65 or CAP90A
sensor)
However, it is possible, as an option, to measure from 50 to 110dB(C) (with CAP40B or CAP90B
sensor)

ERROR LISTING

Error listing which can be displayed by control display.
E2 : Sensor link defect

SPECIFICATIONS

AFF16:
Integrating soundlevel meter
A weighting: Class 2 according to IEC61672-1 juin 2003
C weighting: Class 2 according to IEC61672-1 juin 2003
CAP65: Active pressure transducer
Frequency weighting A : Class 2 according to IEC61672-1 Juin 2003
Frequency weighting Z: Class 2 according to IEC61672-1 Juin 2003
Power supply:
12 Volts, 400mA
Dimensions:
Weight:
2 kg (AFF + Sensor + stand)
INFORMATIONS
Warning !!!
 Never use this equipement without proper grounding.
Never open the case without disconnecting mains
Avoid high temperature exposure.
Never expose the equipment to rain, snow or moisture.
AFF16 complies with :
EN60065, EN55013, EN55020, EN60555-2, and EN60555-3, according to 73/23/EEC, 89/336/EEC
and 93/68/EEC.
AMIX
265 x 150 x 35 mm
26
AFF16

Publicité

Chapitres

Table des Matières
loading

Table des Matières