To determine the offset value:
Just use the sensor moving in the presence of noise to measure.
a - Select a value Leq 1 min with the encoder 5.
b - Position the sensor at the desired measurement level (often the noisiest place). Wait 2
minutes. Note the value of the display (for example 95 dB)
c - Place the sensor where it will be fixed.
Wait at least 2 minutes. Note the value of the display (for example 92 dB)
d - If there is such that the value is 3 dB lower than the first measure, then simply set the switch
to + and the encoder wheel on 3dB to add 3 dB.
The display will then show 92dB + 3dB = 95 dB, and it is the value that you want to display.
This applies to any value between + / - 9dB.
7 ) RJ45 opto mos relay output connector corresponding to alarm level exceeding.
8
OPTO MOS 1
OPTO MOS 2
V+
SENSOR
1
OPTO MOS internal wiring
CMD 2
CMD 1
AMIX
+
v
GPO 1 (dB)
1
on
DC supply
12 V/200 mA
0
Hundred
Ten
Unit
GPO 2 (dB)
Leq
1
0
FAST
on
on
1
1 mn
2
5 mn
3
10 mn
1
0
4
15 mn
Hundred
Ten
Unit
5
30 mn
Light
6
1 H
Auto
7
8
on
9
GPO2
Manual
Leq
C
on
A
GPO1
Offset (dB)
+
on
-
Unit
E2: Sensor link fault
GPO2
Leds GPO1 and GPO2 display GPO1 and GPO2 state.
GPO1
1
2
3
V+
4
5
6
7
8
Note :
Each OPTO can be considered as a relay and offers all
the advantages (alternative signals, no wiring). Current
limit is fixed at 200mA.