Mesuring Range; Error Listing - AMIX AFF15 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REAR PANEL
3 )
6 points removable connector
6
From CAP 20
5
(with phantom supply)
4
3
From SNA
2
(without phantom supply)
1
4 )
B type USB connector. It permits fitters to define the AFF configuration. In the AFF case, it
can be also used to download call data saved in the AFF 20 flash memory.

MESURING RANGE

With A weighted, 10 minute Leq, 5 minute Leq, 1 minute Leq and 1 second Leq range is from
60 dB(A) to 122 dB(A).
However, it is possible, as an option, to measure from 40 dB(A) to 102dB(A).
With C weighted, peak level range is from 50 dB(C) to 122 dB(C).
However, it is possible, as an option, to measure from 50 dB(C) to 112dB(C)

ERROR LISTING

Error listing which can be displayed by control display (B).
E1 : AFF internal error. Use the configuration software to diagnosis the problem (contact your
fitter)
E2 : CAP 20 sensor link defect.
E3 : Date and hour error. Please, could you check the square battery.