Time weighting:
Leq
6 ) Offset setting
AFF16 has a remote pressure sensor. Indeed, the measurement point is often different from the display
point. On the other hand it is often difficult to locate the sensor exactly the same place where you want
to measure.
Sound pressure can be different from the ideal measurement point and where the sensor is actually
located.
The offset adjustment is used to shift the measurement value plus or minus, and dB by dB.
Examples:
+
on
-
Unit
+
on
-
Unit
In case you do not want to use the "OFFSET" function, simply set the encoder wheel to 0 (in this case
regardless of the position + or -).
AMIX
v
+
GPO 1 (dB)
1
on
DC supply
12 V/200 mA
0
Hundred
Ten
Unit
GPO 2 (dB)
Leq
1
0
FAST
on
on
1
1 mn
2
5 mn
3
10 mn
1
0
4
15 mn
Hundred
Ten
Unit
5
30 mn
Light
6
1 H
Auto
7
8
on
9
GPO2
Manual
Leq
C
on
A
GPO1
Offset (dB)
+
on
-
Unit
E2: Sensor link fault
The average sound level measurement is called the Leq (for "Level
equivalent"). The next time the indication is the integration time.
Leq
0
FAST
Depending on the position of the encoder wheel (0-
1
1 mn
2
5 mn
6), the Leq are: Fast, 1 minute, 5 minutes, 10
3
10 mn
minutes, 15 minutes, 30 minutes, 1 hour.
4
15 mn
5
30 mn
6
1 H
7
8
9
The switch on + add to measure the number of dB displayed by the
encoder wheel. In this case +4 dB.
-
The switch on
the encoder wheel. In this case -4 dB
removed to measure the number of dB displayed by