Preparing The Tool For Use; Setting The Air Pressure - RIDGID R350PNE Manuel D'utilisation

Cloueuse de type paume
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION

PREPARING THE TOOL FOR USE

See Figure 2, page 14.
Under normal use conditions, the tool should be lubricated
before connecting the tool to an air supply. Add air tool lu-
bricant into the air fitting on the tool once daily with minimal
use, or twice a day with heavy use. Only a few drops of oil
at a time is necessary. Too much oil will only collect inside
the tool and will be noticeable in the exhaust cycle.
Before connecting the tool, check the air compressor gauge
to be sure it is functioning within the proper range of 50-
120 psi.
WARNING:
Disconnect the tool from the air supply before
leaving the work area, moving the tool to another
location, or handing the tool to another person.
Failure to do so could result in serious personal
injury.
CONNECTING THE TOOL TO AN AIR SUPPLY
See Figure 3, page 14.
DANGER:
Do not use oxygen, combustible gases or bottled
gases as a power source for this tool. The tool will
explode and cause death or serious injury.
This tool is designed to operate on clean, dry compressed air
at regulated pressures between 50 and 120 psi . The correct
air pressure is the lowest pressure that will do the job.
NOTE: Air pressure that is higher than 120 psi may damage
the tool.
The tool and air hose must have a hose coupling that allows
all pressure to be removed from the tool when the coupling
is disconnected.
WARNING:
Always use a coupling that discharges all the
compressed air in the tool at the time the fitting or
hose coupling is disconnected. Using a coupling
that does not discharge the compressed air could
cause unintended operation and serious personal
injury.
WARNING:
Do not climb rigging or scaffolding while carrying
a tool that is connected to an air hose. Doing so
could result in serious personal injury.
Connect the tool to the air supply with a 1/4 in. female quick
connector. A 3/8 in. female quick connector may be used
in situations where a 1/4 in. supply line is not available. For
maximum tool performance, a 3/8 in. supply line and fittings
are required.
LOADING THE TOOL WITH NAILS
See Figure 4, page 14.
WARNING:
The tool's driving mechanism may cycle when the
tool is first connected to the air supply. Always
connect the tool to the air supply before loading
nails to prevent injury from unintended cycling.
Always make sure the nosepiece is empty at the
beginning of each work session, before connecting
to an air supply.
 Connect the tool to the air supply.
 With the nose of the tool pointed away from you, feed
a nail into the nosepiece. Be sure the nails are pointed
downward and at the angle shown.
 Do not hold the tip or head of the nail when feeding into
the nosepiece.
WARNING:
Keep the tool pointed away from yourself and
others when loading nails. Failure to do so could
result in possible serious personal injury.
WARNING:
Never load nails with the nosepiece depressed.
Doing so could result in possible serious personal
injury.

SETTING THE AIR PRESSURE

The amount of air pressure required will depend on the size
of the nail and the workpiece material.
Begin testing the depth of drive by driving a test nail into the
same type of workpiece material used for the actual job.
Drive a test nail with the air pressure set at 50-55 psi. Raise
or lower the air pressure to find the lowest setting that will
perform the job with consistent results.
It may be possible to achieve the desired depth with air
pressure adjustments alone. If finer adjustments are needed,
use the drive depth adjustment on the tool.
9 – English