Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Rainmaker Select 460 2jet 24005400 Mode D'emploi / Instructions De Montage

Masquer les pouces Voir aussi pour Rainmaker Select 460 2jet 24005400:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
The shower may only be used for bathing, hygiene
and body cleaning purposes.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The product is not designed to be used with steam
baths!

Technical Data

Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Head shower extremely leaky
4
English
max. 0,6 MPa
0,15 - 0,4 MPa
max. 60°C
max. 70°C / 4 min
Cause
- Head shower soiled / scaled
Assembly see page 36

Symbol description

Warm water
Cold water
The wall must be reinforced in this area.
Plug the unused outlet.
The waste drain performance must be more
than 50 l/min.
> 50 l/min
Waste
Raindrain
Do not use silicone containing acetic acid!
Dimensions (see page 31)
i
Installation example (see page
32)
Flow diagram (see page 32)
Cleaning (see page 38) and en-
closed brochure
Spare parts (see page 40)
Remedy
- Clean / descale head shower
see page 38

Publicité

Table des Matières
loading