A(mm)
B(mm)
C(mm)
760
50 mini
30 mini
Before you install the hob, make sure that
• the work surface is square and level, and no structural members interfere with space requirements
• the work surface is made of a heat-resistant material
• if the hob is installed above an oven, the oven has a built-in cooling fan
• the installation will comply with all clearance requirements and applicable standards and regulations
• a suitable isolating switch providing full disconnection from the mains power supply is incorporated in the permanent
wiring, mounted and positioned to comply with the local wiring rules and regulations.
The isolating switch must be of an approved type and provide a 3 mm air gap contact separation in all poles (or in all
active [phase] conductors if the local wiring rules allow for this variation of the requirements)
• the isolating switch will be easily accessible to the customer with the hob installed
• you consult local building authorities and by-laws if in doubt regarding installation
• you use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall surfaces surrounding the hob.
When you have installed the hob, make sure that
• the power supply cable is not accessible through cupboard doors or drawers
• there is adequate flow of fresh air from outside the cabinetry to the base of the hob
• if the hob is installed above a drawer or cupboard space, a thermal protection barrier is installed below the base of the
hob
• the isolating switch is easily accessible by the customer

Before locating the fixing brackets

The unit should be placed on a stable, smooth surface (use the packaging). Do not apply force onto the controls
protruding from the hob.
Fix the hob on the work surface by screw four brackets on the bottom of hob (see picture) after installation. Adjust the
bracket position to suit for different work surface‟s thickness.
Cautions
1. The ceramic cooker hob must be installed by qualified personnel or technicians. We have professionals at your service.
Please never conduct the operation by yourself.
2. The ceramic cooker hob shall not be mounted to cooling equipment, dishwashers and rotary dryers.
3. The ceramic cooker hob shall be installed such that better heat radiation can be ensured to enhance its reliability.
4. The wall and induced heating zone above the work surface shall withstand heat.
5. To avoid any damage, the sandwich layer and adhesive must be resistant to heat.
6. A steam cleaner is not to be used.
7. This ceramic can be connected only to a supply with system impedance no more than 0.427 ohm. In case necessary,
please consult your supply authority for system impedance information.
D
E
Air intake
Air exit 10 mm