OPERATION
EMERGENCY STOP BUTTON
(Drive Model - - Option)
To stop the machine in the event of an emergency,
hit the red emergency stop button located at rear of
control console. The emergency stop button
immediately stops all power to machine.
To reset emergency stop button, shut off all switches
and turn red button to the right. Resume normal
operation (Figure 19). Order part number #612971 for
field install kit.
FIG. 19
HOUR METER (Option)
The hour meter records number of hours the machine
has been powered on. Use the hour meter to
determine when to perform recommended
maintenance procedures and to record service history
(Figure 20). Order part number #612939 for the field
install kit.
FIG. 20
12
LOW VOLTAGE PAD SHUT-OFF METER
(Drive Model - - Option)
The Low Voltage Pad Shut-off Meter Option will shut
off the power to the pad motor when the battery
discharge level nears recharging time. This allows the
operator to use the remaining battery charge to
transport the machine to the charging station
(Figure 21).
Meter Operation: As the batteries discharge to a low
level, one LED light on the meter will begin to blink,
signalling the operator it's nearing time to recharge the
batteries. When two LED lights on the meter begin to
blink alternately, the power to the pad motor will
automatically shut off. At this time, transport machine
to charging station.
Order part number #612941 for the field install kit.
FIG. 21
CHARGING BATTERIES
ATTENTION: To prolong the life of the batteries
and to provide optimum machine performance,
ONLY recharge the batteries after a total of 30
minutes of use or more. Do not leave batteries
discharged for lengthy periods.
The following charging instructions are intended for
battery chargers supplied with the machine. Only use
a battery charger with the following specifications to
prevent battery damage.
BATTERY CHARGER SPECIFICATIONS:
S
OUTPUT VOLTAGE - 36 VOLTS
S
OUTPUT CURRENT - 25 AMPS MAXIMUM
S
AUTOMATIC SHUTOFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING