2.4 Electrical connections 
 
2.4.1 Voltage and protection 
 
 the  electrical  supply  to  the  heat  pump  must  pass  via  a  protection  and  disconnection  device  (not  supplied) 
complying with the standards and regulations in force in the country, 
 the device is designed for connection to a general power grid with TT and TN.S grounding systems, 
 electrical protection: circuit‐breaker (curve D) or fuse (Am) (calibre 16A), with a dedicated 30 mA differential trip 
switch (circuit‐breaker or switch), 
 
 Acceptable tolerance for tension variation: ‐10%, +7% (while operating). 
 
 
2.4.2 Connections 
 
 the electrical supply cable must not be exposed to elements that are sharp, hot or represent a crush hazard,  
 check that all cables are secure and all terminal connections are correct, 
 Use a RO2V electrical supply cable to connect the 11kW appliance, 
 
 electrical conduits must be secured, 
 use the stuffing box to bring the supply cable into the appliance, 
 loose terminals may cause the supply terminal board to overheat, and will void the warranty, 
 the appliance must be earthed, 
 
 risk of electrical shock inside the device, 
 only  a  fully  qualified  and  approved  technician  should  perform  cabling  connections  inside  the 
appliance, 
 if the power cable is damaged it must be replaced by a qualified technician. 
H04019‐00.A3.EN – 2013/01
ML1_Pac Alpha Ed 01-2013-noir.indd 15
 
 
5M 
bar 
bar 
mCE 
2.3 
m³/h 
m³/h 
m³/h 
 
* minimum distance  
 by‐pass  
 filter  
 water treatment 
VE : water inlet valve 
VS : water outlet valve 
VB : by‐pass valve 
 
7M 
1.5 
2.45 
 
9M 
11M 
4.95 
16/01/13 11:05
EN 