Optional Flue Connector Kit; Masonry And Factory Built Fireplace Clearances - Regency I3105L Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour I3105L:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Position the grill on the inside bodyface side and
fasten using the bolts, washers and nuts provided
(2 per side) as shown in the diagrams.
Note: The grill has a front and rear, the holes
on the front side have rounded edges
and the rear holes have flat edges.

MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES

The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below.
Adjacent
Side Wall
Unit
(to Side of
Unit)
A
Large Flush
13"/330mm
Insert I3100L
Hearth Heater
H2100M
10"/255mm
Side and Top facing is a maximum of 1.5" thick.
Floor protection must non-combustible, insula-
tive material with an R value of 1.1 or greater.
*
If the hearth extension is flush with the floor
(F) it must extend 19.5" in front of the body
face (E).
Note: Hearth Extension Width (G) is meas-
ured from edge of fuel door to side
of hearth.
** A non-combustible mantel may be in-
stalled at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
** Mantel depth - maximum of 10" (254mm)
Thermal floor protection is not required if the unit is
raised 3.5" minimum (measured from the bottom of
the stove). However, standard ember floor protec-
tion is required. It will need to be a non-combustible
material that covers 16" (406 mm) in the US and
18" (450 mm) in Canada to the front of the unit and
8" (200 mm) to the sides.
If the unit is not raised, thermal floor protection
required is 18" (450 mm) in the US and Canada.
Mantle**
Top
(to Top of
Facing
unit)
(to Top of Unit)
B
C
19"/480mm
18"/455mm
25"/635mm
14"/355mm
View from Rear of Insert
Side
Minimum
Facing
Hearth
(to Side of Unit)
Extension
D
E
6.5"/406mm
16"/406mm
8.5"/216mm
18"/455mm
H
Clearance diagram for installations
installation
OPTIONAL FLUE
CONNECTOR KIT
The optional Flue Connector Kit (Part # 846-527)
and the Straight Flue Adaptor (Part #846-504)
shown here, may be used to produce a secure
connection between your flue connector and the
insert collar. Detailed installation instructions are
included with the kit.
Minimum
Minimum
From Top of
Hearth
Hearth
Thickness*
Extension
Side
F
G
1.5"/38mm
8"/205mm
23-1/4"/603mm
1.5"/38mm
6"/152mm
15-3/4"/400mm
H2105 / I3105 | 7
|
7