Master B 18 EPR Manuel D'utilisation Et De Maintenance page 27

Table des Matières

Publicité

WARNING !!!: The heater is fitted with a phase
control relay which monitors correct phases con-
nection. The relay prevents the ventilator engine
from rotating in the wrong direction. If the signal
light no 11 remains lit for more than 2 seconds, it
means that a phase is missing or phases are con-
nected in wrong order. In such case, please check
device phase connection or change phase order in
the power supply socket.
Make sure the power supply cable has not been damaged. If the
supply cord is damaged, it must be replaced by the manufac-
turer, its service agent or similarly qualified persons in order to
avoid a hazard. Moreover, check if the technical parameters of
power supply source comply with the requirements specified on
the rating plate. Place the appliance in its upright position. Make
sure the switch is in its "0" position shown in Fig. 3. Connect the
heater to the power supply source. Turn the switch and leave it
for 5 seconds in the positions as follows:
► Fan only: Fig. 3;
► 1st degree of heating: Fig. 3, and
► 2nd degree of heating: Fig. 3.
►►5. SWITCHING OFF
Turn the switch to its "0" position. Once the heating is off, leave
the fan operating for 3 minutes.
►►6. WORK WITH THE HOSE DISTRIBUTING
HOT AIR (FIG. 7)
The appliance is adapted to work with a hot air hose distributor up 100
C. The hose distributing hot air of Ø305 mm (B 18 EPR) / Ø407 mm
o
(B 30 EPR) and max 15m length shold be connected to the out-
let. After connection make sure that the hose is patent and not
folded to let the air flow property.
►►7.
THERMAL
CIRCUIT
The appliance has been equipped with an integrated thermal
circuit breaker ensuring high safety level. The breaker will au-
►►11. TROUBLESHOOTING
PROBLEM
The motor operates while the appliance does
not heat.
The motor does not operate while the heating
elements are hot.
The whole appliance does not operate.
Reduced air flow.
Heater won't start. Signal light no. 11 is lit for
more than 2 seconds.
BREAKER
"RESET"
REASON
Thermal circuit breaker is active.
Thermostat has been damaged.
Relay has been damaged.
Heating element has been damaged.
Motor has been damaged.
Fan has been stopped.
Switch has been damaged.
Electric circuit open.
Switch has been damaged.
Foul air duct.
Motor has been damaged.
Wrong phase order
Missing phase
tomatically switch the power supply off once a limit temperature
is exceeded. Should it happen, let the appliance cool down and
only then, look for the reason of the problem. Next push the
"RESET" button (Fig. 4) with a pointed tip in order to unlock the
thermal circuit breaker. If the heater does not operate, contact
the seller or approved service centre.
►►8. OUT-OF-SEASON STORAGE
Should the appliance remain idle for a long period of time, clean
it before shoving by blowing the inside with compressed air. The
heater should be kept in a dry and clean place. Before you start
using it again make sure the power supply cable has not been
damaged. In the case of any doubts contact the seller or appro-
ved service centre.
►►9. FUNCTIONAL INSPECTION
The appliance should be checked at least once a year by com-
petent service personnel approved by the manufacturer. Any
inspections or repairs should be conducted by competent per-
sonnel only.
►►10. EXTERNAL THERMOSTAT
The appliance may work with external thermostat.
Heating without room termostat
The unit runs under continuous duty.
► Connect the supplied bridge circuit plug 2 fig 6 to the thermo-
stat socket 1 fig 6 of the unit.
► Put the switches into the desired position
► WARNING!!! For optimum unit operation, the device should
not be operated at an ambient temperature above 25 °C.
Heating with room thermostat
The unit runs fully automatically and is dependent on set
temperatures.
► Remove the bridge circuit plug 2. fig 6
► Connect thermostat plug 3 fig 6 of the room thermostat (ac-
cessories) to the thermostat socked 1. fig 6
► Put room thermostat 4. fig 6 in a suitable place. The thermo-
stat sensor may not be exposed directly to the hot air current
and not fixed directly on a cold surface.
► Pre-select desired room temperture on the room thermostat.
► Put the switches (fig. 3) into the desired position.
Let the heater cool down and push the
Replace the heating element.
Check power supply connection.
Change the phase order in the heater's power
Check the electrical installation.
SOLUTION
"RESET" button .
Replace the thermostat.
Replace the relay
Replace the motor.
Unlock / clean the fan.
Replace the switch.
Replace the switch.
Open the air duct.
Replace the motor.
supply socket.
AL
BG
CZ
DE
DK
EE
ES
FI
FR
GB
GR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK
TR
UA
YU

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B 30 epr

Table des Matières