Alarm
OFA First Alarm (time >70%)
OFA Second Alarm (time =100%)
Flow Rate
System Error
Calibration Funciont
Default parameters:
Language = UK
Set Point value= 7,4 pH; 750mV (Rx)
Dosing Method = Acid; Low (Rx)
Time OFA = OFF
Calibration = 7/4 (2 point); 465mV (Rx)
Flow Input= OFF
Code 0000137847
Display
OFA Alarm
OFA STOP
Flow
Parameter Error
Error 7 ph Error 4 ph
Error 465 mV
To restore Default parameters run Following steps:
Rev 1.0
- Push Enter Key to reset
- Push Enter Key to reset
- Restore Flow Rate
- Press Enter Key to replace Default parameter
- Destroy Unit
- Restore Probe or Buffer
solution and repeat calibration function
Power off Pool Basic unit
Keep pressing both buttons simultaneously
and
To turn on the system Basic.
The system will show Default No
Press
for Default Yes
Press
to restore Default parameters.
Actions to do
6