Level 1 and 2 Programming, for Performa FA with 742
Press UP and DOWN arrow to enter Level 2 programming
Param.
Parameter description
P1
Time
P2
Day of week
P3
Time of Regen
P4
Forced Regen Interval
P5
Regen Interval (only 742)
P6
Backwash Time
P9
Unit of measure (0=english , 1= metric)
P10
Clock mode
P11
Service internal
P12
Remote regen sw. Delay
P13
Chlorine generator (0=non, 1=salt check only, 2=generate chlorine and check salt)
P14
Refill rate
P15
Brine Draw rate
Level 3 Programming, for Performa FA with 742
Press SET and DOWN arrow to enter Level 3 programming (Cycle Time programming)
Param.
Parameter Descrip.
C1
Backwash 1 Time
C2
Brin Draw Time
C3
Slow Rinse Time
C4
Repressurize Time
C5
Fast Rinse 1 Time
C6
Backwash 2 Time
C7
Fast Rinse 2 Time
C8
Refill Time
NOTE : 1 cuft (28 L) of Manganese Greensand is regenerated by 1 gallon of Saturated Potassium Permanganate solution
Unit
HH:MM
Days
HH:MM
Days
only 742 - Days if P4 set to 0
Minutes
(0=12h ; 1=24h)
Monthes
s
gpm x 100
gpm x 100
Unit
Value
Minutes
20
Minutes
Depend on
Use the draw charts value or injectors
manganese
Greensand
quantity
Draw time = Volume to draw (in gallons) /
draw rate (gpm) OR Draw time = Volume
Minutes
Depend on
Refer to Manganese green sand manufacturer
manganese
Typ. allow minimum 3 BV slow rinse :
Greensand
quantity
(3xBV) (gallons) / slow rinse rate (gpm) OR
Minutes
1
Minutes
Depend on
Refer to Manganese green sand manufacturer
manganese
Greensand
quantity
(2xBV) (gallons) / fast rinse rate (gpm) OR
Minutes
0
Minutes
0
Minutes
9
Comment
curves to determine Brine draw rate
then use the formula
to draw (in L) / draw rate (L/min)
Use the formula : Slow rinse time =
Slow rinse time = (3xBV) (Liters) /
slow rinse rate (L/min)
Typ. allow minimum 2 BV fast rinse :
Use the formula : Fast rinse time =
Fast rinse time = (2xBV) (Liters) /
fast rinse rate (L/min)
No Refill flow control
on Performa FA version
37
Value
Comment
Set time of day
Set day of week
Those values
Set time of regen
are also
Set interval
accessible
between regen
from Level 1
if P4 set to 0 you
programming
can set specific
days of the week
20
1
1
0
60
0
Do not use with
KMnO4
Not used
Not used
Brine Draw time
is entered directly
in level 3 program
Example
Example to draw 1 gallon
(3.78 L) of KMnO4 solu-
tion, with injector J @ 50
psi; Draw time =
3.78/0.98 = 4 min.
Exemple to rinse
25 L of media using
injector J @ 50 psi;
Slow rinse time = (3x25)/
1.1 7 = 64 min.
Example to rinse
1 Cuft of media in
a 10" vess. diam. with
6 gpm DLFC : Fast
rinse time = 2x25 /22.5
= 3 min.
Permanganate feeder
must be used
(with float level control)