7. Draw water from the regenerant tank.
A. From the treated water position (cycle C0), advance the
valve to the draw regenerant position. Hold the REGEN
button down for five seconds.
The controller will begin a manual regen, and advance the
control valve to the cycle C1 (Backwash). Press the SET and
UP button to advance to cycle C2 (Draw).
B. With the controller in this position, check to see that the
water in the regenerant tank is being drawn out of the tank.
The water level in the tank should recede very slowly.
C. Observe the water being drawn from the regenerant tank for
at least three minutes. If the water level does not recede, or
goes up, check all hose connections. C2 should be
displayed.
8. If the water level is receding from the regenerant tank you can
then advance the controller back to the treated water (C0) posi-
tion by pressing SET and the UP buttons simultaneously to
advance the controller to the C0 position.
9. Finally, turn on a faucet plumbed after the water conditioner.
Run the faucet until the water runs clear.