Putting Into Service
DIAGNOSE – This screen allows the operator to troubleshoot connection issues between the placing tool and the
pump by displaying if the microprocessor has received a signal from the trigger button. No signal indicates the
problem is most likely with the trigger or trigger control cord.
00001 BAR displayed when placing tool trigger button is not activated.
01001 BAR displayed when the placing tool trigger is pressed.

Return Timer Setting

The pump has an adjustable Return Timer that allows operator to set the length of time that the motor will run, after
releasing the trigger or achieving the 'High Pressure' value, before switching to idle mode.
The timer can be set at any value between 5 and 20 seconds, but must be adjusted to allow the placing tool piston
sufficient time to fully return before switching the motor off.
The following timer settings are recommended for the Avdel
TOOL PART NUMBER
TOOL MODEL
ZU4 Pump – Timer Setting
ZE4 Pump – Timer Setting
ZE6 Pump – Timer Setting
The process below explains how to correctly set the Return Timer.
Connect the unit to the power supply and switch on as described on pages 11 and 12.
Press the MENU button on the LCD screen until the 'RET TIME' menu is displayed.
Use the Up and Down Arrows to adjust to the timer in 1 second intervals to the desired value.
Save the setting and return to the 'AVDEL' display by pressing and holding the MENU button for 2 seconds. The
timer is now set.
SCREEN 12
DIAGNOSE
00001
BAR
®
range of placing tools and pumps.
PUMP RETURN TIMER SETTING
73430-02000
73432-02000
AV™10
AV™15
5 seconds
5 seconds
5 seconds
5 seconds
5 seconds
5 seconds
73435-02000
73434-02000
AV™50
AV™30
10 seconds
8 seconds
10 seconds
8 seconds
6 seconds
5 seconds