Read Sensor Settings - Sensopart FT 50 RLA-70-L8 Instructions De Service Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Example telegram
(in the example, the sensor has the address 1, it is switched to 2)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Data
5. Byte
Check sum
8.5.22

Read sensor settings

Command (Byte 3):
Parameter:
Reply (Byte 3):
Parameter:
76
Decimal
Hex.:
129
81
5
05
76
4C
2
02
74
4A
decimal 63; hexadecimal 0x3F
no
decimal 89; hexadecimal 0x59
Function 1
D8: Trigger input
D9: Q
is enable input
1
D10: X
D11: Maximum hold
D12: Difference hold
D13: Q
is software input
1
D14: fast measuring value output
D0: Q
is signal output
1
D1: Q
is scanning zone
1
D2: Q
is signal output inversion (1 = N.C.)
1
D3: Q
is signal output pulse stretching
1
D4: Minimum hold
D5: Autom. zero
D6: Autom. centre
Function 2
D8 ... D14: Identifikation of variants
D0: Q
is signal output
1
D1: Q
is scanning zone
1
D2: Q
is signal output inversion (1 = N.C.)
1
D3: Q
is signal output pulse stretching
1
D4: Q
ist good target output
2
D5 ... D6: X
Function 3
D8: Measured value hold
D9, D10: X
D11: Key lock
D12 ... D14: X
D0: Mean value 0,4 ms
D1: Mean value 4 ms
D2: Mean value 40 ms
D3 ... D6: X
Characteristic curve 4 mA point
Characteristic curve 20 mA point
Switching threshold Q
1
Scanning zone Q
1
Switching threshold Q
2
Scanning zone Q
2
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
Parameter format
12 bit data item: data 2
12 bit data item: data 2
12 bit data item: data 2
12 bit data item: data 1
12 bit data item: data 1
12 bit data item: data 1
12 bit data item: data 1
12 bit data item: data 1
12 bit data item: data 1
FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
Decimal
Hex.:
129
81
4
04
89
59
92
5C