2.
TECHNICAL DATA
2.1 TECHNICAL DATA
Model
Thermal power
Natural gas -
(Family 2)
LPG - (Family 3)
Electrical supply
Motor
Ignition transformer
(1) Reference conditions:
Air temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
2.2 OVERALL DIMENSIONS
2.3 GAS CATEGORIES
Country
Natural gas
G20
Pressure
(mbar)
G25
Country
LPG
Pressure
G31
(mbar)
G20
Net calorific value: 9.45 kWh/Sm
G25
Net calorific value: 8.125 kWh/Sm
G31
Net calorific value: 24.44 kWh/Sm
Single-phase,
Primary 220V - 240 - 50 - 60H
3 2 3
IT - GB - AT - DK - IE - ES - GR - PT
NO - SE - FI - CZ - CH - EE - LT
I2H
20
25
IT - GB - AT - IE - ES - GR - PT
CZ - CH - DE - FR - BE
I3P
29
RX 120 S/PV
25
120 kW
-
21.500
to
3
= 8,100 kcal/Sm
3
= 7,000 kcal/Sm
3
= 21,000 kcal/Sm
~
50/60Hz 220/230 V
Max. 6000 rpm - 50/60Hz
z
3 4 2
LV - PL - LU
I2E
20
25
3
GB
103.200 Kcal/h
to
3
- Pressure 15 - 30 mbar
3
- Pressure 15 - 30 mbar
3
- Pressure 15 - 30 mbar
±
10%
– Secondary 15 kV - 25 mA
5 6 8
1 1 7
I2ELL
I2Er
DE
FR
20
20/25
25
25
D9766
I2E(R)B
BE
20/25
25
3328