Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mounting informations
The drive will be full configured by factory.
The drives must be reconfigured in case of
alterations (e.g. removing of drives
from existing set or integrating
a new drive) with SCS.
At vertical active pulling application (e.g. for a
skylight) the forces must be rearranged by software
SCS

Pin Assignment

Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Connection: page 18 - 20
Shift of drive cable
99.823.89 2.4/12/13
Slave 1
Option -BRV
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Only for ex-works programming
Debe ser encendido OFF
English
Mount the drives mechanical stress-free.
With that, a better load distribution
is ensured on all the drives.
If after mounting the measure x is as bigger as
23 mm, null balance with software SCS is neccesary.
Closure Ranges will shift in relation to new zero
point.
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (- SGI / SKS)
PK (+ SGI / SKS)
The connecting cable is directly connected
to the drive and not changeable
DIP-Switch
X
≥ 23 mm ?
Option -SA/-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SA / -SZ)
PK (-SA / -SZ)
7/20