Electronic Control; Battery Protection - Indel B TB Série Instructions D'utilisation

Masquer les pouces Voir aussi pour TB Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
TB SERIES
USING THE REFRIGERATOR AT HOME
- This model can be fed equally using 12/24V or mains power (100V - 240V AC).
- It is equipped with 2 sockets to connect the two different cables for DC respectively AC.
- The refrigerator is provided with automatic switch over from one kind of feeding to the other.
- Should both be present at the same time, the device will always set itself on mains power priority feeding
by 100V~240V AC.

ELECTRONIC CONTROL

Compressor station
Functions and features.
This is an electronic device which has the function of piloting the motor of the compressor and carrying
out all the controls and electrical protection of the system.
Its main features are as follows:
a) Protection of the battery through automatic turning off of the compressor when the feeding voltage
reaches the minimum threshold.
The compressor will start up again automatically when the voltage goes back to normal values.
Note: these values have been measured at control unit input and/or on the DC socket.

Battery protection

(SWITCH POSITION)
LOW
MED
HIGH
TB_SERIES_27-04-2018
TB45A-TB55A
L O
W
H I
G H
M E
D
Cut-out 12V
Cut-in 12V
9.6
10.9
10.1
11.4
11.1
12.4
TB31A-TB41A-TB51A
D C
1 2
V /
2 4
V
F U
S E
A C
1 1
0 -
1 2
0 V
/ 2 2
D C
0 -
2 4
1 2
0 V
V /
2 4
V
1 5
A
5 0
H Z
/ 6
0 H
Z
Cut-out 24V
21.3
22.3
24.3
ENGLISH
189A0757
Cut-in 24V
22.7
23.7
25.7
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tb31aTb41aTb51aTb45aTb55a

Table des Matières