1. The pump is not discharging
any liquid, the motor is not
running.
2. The motor is running, but the
pump is not discharging any
liquid.
C
M
Y
CM
MY
CY
CMY
K
3. The pump stops after a short
time of operation because the
thermal motor protection
feature has triggered.
4. The pump does not reach the
desired pressure.
5. The pump vibrates.
16
MALFUNCTION
1. No current.
2. Thermal motor protection feature has
triggered.
3. The capacitor is defective.
4. The motor shaft is jamming.
5. Inlet pressure is too low and generally
accompanied by cavitation noise.
6. Insu cient voltage.
1. The pump housing is not lled wit h liquid.
2. Air penetrates into the intake line.
3. Suction height and/or discharge height too
great.
1. The electrical supply does not correspond
to the information given on the type plate.
2. Pump or intake line is blocked by solids.
3. Liquid is too viscous.
4. Temperature of liquid or envir onment is
too high.
1. Refer to section 2.2.
2. Worn pump wheel .
1. Anchorage on a faulty base.
2. Foreign bodies obstructing the pump.
3. Obstruction to the pump rotation.
18
27.04.2018
09:06:11
POSSIBLE CAUSE
1. Please use a device complying with GS
2. Separate the pump from the electrical
3. Please contact the customer service
4. Check the cause; eliminate the reason for
5. Excessive loss of head in suction or the
6. Check the voltage of the motor terminals.
1. Fill the pump housing with liquid (please
2. Check to make sure that:
3. Change the arrangement of the installation
1. Please use a device complying with GS
2. Remove possible congestion.
3. Pump may not be suitable for this
4. Make sure that the temperature of the
1. Refer to section 2.2.
2. Please contact the customer service
1. Check and fully tighten the nuts on the
2. Dismantle the pump and clean it.
3. Check that the pump can rotate freely
7
ELIMINATION
(German technical supervisory authority)
to check for the presence of voltage
(safety information to be observed!).
Please verify the correct position of the
plug.
mains, allow the system to cool down,
eliminate cause.
department.
the jamming of the pump.
sucti on height is excessive (check the
NPSH of the installed pump).
The voltage should be ± 10% of the rated
voltage.
refer to "Putting into operation" section).
a.) the connection points of the intake line
are tight;
b.) the inlet opening of the intake line
including the check valve (non-return
valve) are immersed into the liquids
being discharged;
c.) the check valve (non-return valve) with
the lter is tight and not jammed;
d.) no siphons (i.e. permanently liq uid-
lled loops), kinks, counter -slopes or
narrow spots are present along the
intake lines.
so that the suction height and/or discharge
height will not exceed the max. value.
(German technical supervisory authority)
to check the voltage of the lines of the
connection cord (safety information to be
observed!).
liquid. If
feasible, the liquid should be thinned.
liquid being pumped and the environment
do not exceed the max. admissible values.
department.
bolts of the studs.
without any abnormal resistance.