11. Troubleshooting
Fault
Engine does not start
Generator has too little or no
voltage

12. Maintenance schedule

Regular service period
Perform at every indicated
month or operating hour
interval, whichever comes
first.
ITEM
ir cleaner
Spark plug
Spark arrester
Combustion chamber
Fuel tank and filter
Fuel tube
Remark:
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, Refer to the manual for service procedures.
Failure to follow this maintenance schedule could result in non-warrantable failures.
16
Spark plug fouled
No fuel
Battery voltage too low
Controller or capacitor defective
Overload cut-off has triggered
Air filter dirty
Each
use
Check
O
Clean
Check- adjust
Replace
Clean
Clean
Clean
Check
Cause
First
Every
month
or
months
20 Hrs.
50 Hrs.
O (1)
After every 300 hrs. (2)
Every 2 years (Replace if necessary) (2)
Remedy
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / check the petrol cock
Charge the battery
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter
Every
3
6
months
or
or
100 Hrs.
O
O
O (2)
Every
year
or
200 Hrs.
O

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

160.100.720

Table des Matières