11
Connecting the filter system
CAUTION!
• The electrical connection of the filter pump must be made by a qualified electrician.
• The power supply must be disconnected with the differential circuit breaker (FI) before any work is carried out on the unit.
11a - Mount the pool filter according to the instructions for use.
11b - Example of sand filtration installation.
Be sure to follow the instructions for use given in the instructions accompanying the sand filtration kit.
12
Connecting the heat pump to the sand filtration kit
12a - Mount the PVC pipes and fittings as shown in the illustration. Note: Before gluing, first proceed with a dry assembly to check that all parts fit together.
• Clean the hose and connecting parts with the paint stripper.
• Do not use abrasive paper to clean the smooth PVC pipe.
• After cleaning, the surface must be matt. Do not touch the surface again as soon as it has been cleaned.
• Apply the adhesive along the longitudinal axis of the pipe and the connecting pieces.
• Assemble the two parts after applying the glue. Insert the parts fully into each other without turning them and hold them together for a few moments.
• Then remove the excess glue with a brush.
12b - Set the by-pass for operation
• For operation with the heat pump: Open valves 1 and 3, close valve 2.
• For operation without the heat pump: Open valve 2, close valves 1 and 3, as shown in diagram 12b on page 54.
Be sure to comply with the operating instructions given in the instructions accompanying the heat pump.
13
Connection of the automatic bottom vacuum cleaner - the Poolcleaner vacuum cleaner is optional. It is not included
in the equipment provided
13a - Insert the pressure regulator into the rubber adapter. Make sure the direction is correct.
13b - Reassemble the automatic brush hose and connect it to the free end of the pressure regulator. It is important to purge it of air. Plug in the assembly kept
immersed in the brush socket. Open the shut-off valve of the brush socket and close the one of the skimmer. Switch on the pump. If the brush is not used,
close the shut-off valve of the brush socket and open the one of the skimmer. Refer to the automatic broom manual for more details.
14
Electrical cabinet
CAUTION!
• The installation of the electrical box as well as the connection of the filtration pump, the heat pump, the control unit of the
jetstream and the pool lighting must be carried out by a qualified electrician.
• The power supply to the box must be disconnected with the differential circuit breaker (FI) before any work is carried out on the unit.
• The electrical box must not be used as a junction box for connections outside the system.
14a - Have the filter pump, heat pump, jetstream control unit and lighting of the pool connected by a qualified electrician.
14b - Set the analogue timers for the filter pump and pool lighting to the hour by turning the minute hand in the direction of the arrow.
14c - The selection switch on both timers allows you to manually turn the filtration pump and pool lighting on and off or to order them by defining schedules.
In the ring area, the times for which you want to set the times are displayed. Push the teeth whose power supply must be cut inwards, the remaining teeth on
the outside now represent the time at which the power supply must remain active.
I
Illuminated
timer
O
Off
In the ring area, the times for which you want to set the times are displayed. Push the teeth whose power supply is to be cut inwards, the remaining teeth on the
outside now represent the time at which the power supply is to remain active.
15
Use of the jetstream installation
CAUTION!
• Only start up the system when the tank is full. It is essential to avoid any dry running of the pump.
15a - Fill the basin with water up to half the maximum skimmer height.
15b - Open both slides and switch on the system with the PN switch.
15c - Adjust the water flow by turning the front inner nozzle. The maximum water flow is obtained by turning the nozzle to the left. Turn the nozzle to the right
to reduce it.
maximum flow rate
15d - Adjust the air addition by turning the front outer nozzle.
15e - Adjust the nozzle to a jet so that the float is opposed to the maximum jet.
Troubleshooting instructions
Problem
The pump makes a lot of noise wit-
hout providing normal power.
The pump makes a lot of noise and
provides maximum power.
The pump does not start or starts
slowly and with difficulty.
The FI switch reacts during
ignition
The engine safety switch turns off.
The pump cannot be switched on from
the tank.
minimum flow rate
Possible cause
The engine is running in the wrong direction.
The water level is not high enough.
The pump sucks in air.
The slide is not fully open.
The suction pipe is not watertight.
The pump is blocked (by leaves etc.).
Friction of the engine cover.
The fan cover is too loose.
A phase is missing.
Bad fuses
Have the installation checked by an electrician.
Incorrect setting.
The pump overheats.
A phase has been skipped.
The switch pipe is bent or jammed.
Switching hose too long.
Fuses/power supply/power supply/motor safety
switch
Recommended action
Reverse the motor poles by exchanging the phases
Add water.
Check that the connections do not leak.
Open the slide.
Seal the suction pipe.
Clean the pump.
Fix it correctly.
Fix it correctly.
Modify the power supply.
Use a 16A time delay fuse
Set the correct electrical value by +10%.
Allow the engine to cool and restart it.
Check the fuse.
Check that the pump can be switched on from the electrical box.
Switching hose too short.
Check the fuses/power supply/test the motor safety switch
50