Abicor Binzel MB GRIP 15 AK Mode D'emploi page 27

Masquer les pouces Voir aussi pour MB GRIP 15 AK:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PSB
5.4 Equipping the torch body
WARNING
All manual plasma-cutting torches are equipped with a torch-specific fuse
terminal for protection of the operator.
To disconnect the wear parts, it must be removed, automatically interrupting
the switch-on circuit. Independently of this safety switch-off circuit, the
plasma power source must be switched off in any case when replacing wear
parts!
CAUTION
Soiled nozzle bores reduce air throughput and cooling. This increases the
wear to all equipment parts, ultimately destroying the torch body.
Always ensure that the protective cap and all wear parts are clean and
properly seated.
1 Screw in electrode and tighten it using a multiple wrench.
2 Screw in the selected plasma nozzle and tighten it using a multiple wrench.
The selection of the plasma nozzle is determined primarily by the material
to be cut and the current intensity.
The following standard values apply:
 Tab. 5 on page EN-5
Depending on the torch version, further wear parts must be used.
Observe their correct sequence as shown in the following figures and the
current order documentation.
3 Tighten protective cap hand tight.
4 Insert fuse terminal.
5 Putting into operation
EN - 9