Clearance to non-combustible wall
We recommend a minimum clearance to non-combustible material of at least 2" (50
mm) so that cleaning is easy. The cleaning door of the chimney should be acces-
sible at all times.
Clearances may only be reduced by means approved by the regulatory authority.
Floor protection
Floor protection must be non-combustible material extending beneath the stove, and
to the front and sides from door opening and to rear as indicated.
Report No. # 0138WS017S
The size of the floor protection is dependent, of installation with or without pedestal.
and is different in US compared to Canada. See User Manual pages 12 & 15 for
more information.
Report No. # 0138WS017S
Thermal Floor Protection
Non-combustible ember protection with an R = 0 is required.
17
FLOOR PROTECTOR
FLOOR PROTECTOR
8"
8"
See further floor protection requirements
at bottom of this label.
See further floor protection requirements
Floor protection for
at bottom of this label.
Canada: 30" (76 cm)
from unit to front of floor protector.
Floor protection for
Canada: 30" (76 cm)
Floor protector must be under the pipe and 2"
from unit to front of floor protector.
(5cm) beyond each side for back venting.