Chimney

RAIS stoves must be installed using a Class A UL 103 HT approved factory-built
chimney system or a code-approved masonry chimney with a flue liner. In Canada,
the appliance must be connected to a factory-built chimney conforming to CAN/ULC-
S629.
The chimney pipe must be 6" in diameter.
The chimney must extend through the roof at least 3' (1m), and 2' (.6m) above any
structure within 10' (3m).
The condition and height of the chimney are very important for optimal use of the
stove and we recommend a total minimum height of 10' (3m).
Note the chimney connector pipe should not pass through an attic, roof space,
closet, concealed space, floor or ceiling.
where passage through a wall, or partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365, installation Code for Solid Fuel-
Burning Appliances and Equipment.
DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE OR AIR DISTRIBUTION
DUCT OR ANY SYSTEM SERVING ANOTHER APPLIANCE.
NEVER MAKE "MAKE-SHIFT" COMPROMISES WHEN INSTALLING THE HEAT-
ER OR CHIMNEY. CHIMNEY CONNECTOR SHOULD BE IN GOD CONDITION
AND KEPT CLEAN
Each chimney connector or stove pipe section, must be installed to each other with
the crimped end toward the stove. This prevents any amount of condensed or liquid
creosote from running down the outside of the pipe or the stove top.
Fasten the connector pipe to the flue collar with 3 self tapping/drilling screws through
the holes in the flue collar.
10
Male
Female
VIVA L USA - US English