Technical Data
Minimum flow pressure
Operating pressure
Recommended operating pressure
Test pressure
Hot water temperature
Temperature scale
Safety stop
Flow capacity at 3 bar
Hand shower (1)
Body showers, 5 jets (2)
Hand + body showers (3)
Handshower
Shower holder
Shower hose
Tray
Bodyshower
Triostat
(Thermostic mixer with shut off
and diverter unit)
Sidecover (Wall installation)
Frontcover
Aluminium profile
0.2 MPa
max. 0.1 MPa
0.2 –0.5 MPa
1.6 MPa
max. 70°C
20 – 60°C
38°C
10,8 l/min
11,8 l/min
14,5 l/min
Ausstattung / Technische Daten
Équipement/Caractéristiques techniques
Flow heater:
Applicable for flow heaters at min. 24 kW and 1.5 bar flow
pressure before the Shower panel. Only one consumer possible,
not two simul-taneously.
Pressure differences:
The pressures of the cold and hot water connections must be bal-
anced.
Maintenance:
The non return valves must be checked regularly according to
DIN EN 1717 in accordance with national or regional regula-
tions (at least once a year).
non return
valve
Fittings / Technical Data