• Never use accessories other than those recommended by the manufacturer. Failure to do
so could pose a safety risk to the user and could damage the appliance. Only use original
parts and accessories.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge.
• This appliance must not be used by children under any circumstances.
• Keep the appliance and its cord out of reach of children.
• Always disconnect the appliance from the mains if it is left unattended or is not in use,
and before assembly, disassembly or cleaning.
• Never leave the appliance unattended during use.
How to use
• Make sure the tap is closed.
• Fill the appliance up to the MAX level indicated on
the inner wall of the reservoir.
• Fasten the lid securely by turning it until it locks
into place.
• Switch the appliance on by setting the dial to po-
sition 1.
After use / Empty the urn
EN
• Switch the appliance off by pulling the plug out of
the wall socket.
• Place a container under the tap.
Maintenance tips
• Always pull the plug from the wall socket before
cleaning the urn.
• If the boiler is subjected to heavy use, you will
need to de-scale it at regular intervals.
• Never immerse the boiler in water or other liquid
cleaning products.
Defects
Defect
Boiler does not work at all.
Boiler switches off
automatically.
Boiler does not reach the
selected temperature.
When in doubt always contact your supplier!
4
Problem
Neither red light
nor indicator light is
illuminated.
The red light is not
illuminated.
Green light is not
illuminated.
• Use the thermostat knob to select the desired
temperature (Maximum temperature setting is
100°C). The actual temperature can differ from
the selected temperature
• When the liquid has reached the selected tem-
perature, the green light will be illuminated.
Note: This appliance is not suitable for use with
milk and chocolate milk.
• Open the tap and drain the liquid out of the urn.
• When the boiler has been emptied, close the tap.
• Clean the boiler with a damp cloth.
• Never use abrasive or caustic cleaning products.
• Always ensure the electrical connections remain
absolutely dry.
• When you drain off dirty water, leave the tap open
and rinse the boiler with clean water.
Cause
No mains voltage.
Boiler has exceeded
maximum safety limits.
Thermostat does not work.
Heating element does not
work.
Possible solution
Check the electrical
connections.
Once it has cooled off, the
boiler will switch on again
automatically.
Contact your supplier.