Start-up
Important:
● The unit turns on automatically when power connection is established.
1. Turning on: Connect the unit to the outlet.
2. Switching off: Unplug the unit from the outlet.
Note:
A brand-new pump will only achieve its maximum capacity after several operating hours.
During start-up, the pump automatically undergoes a pre-programmed self-test of approx. two minutes (Environmental
Function Control (EFC)). The pump runs through various speeds and detects whether it runs dry (is blocked) or
is submerged. The pump switches off automatically after approx. 90 seconds if it runs dry (is blocked). The pump
automatically makes new attempts to start up at regular intervals. In the event of a malfunction, disconnect the
power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate
the units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
• Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
• In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can be
used. Subsequently, clean the pump thoroughly using clear water.
Cleaning the pump
1. Remove the screws and pump
housing.
2. Open the clips (A) and remove the
strainer top casing
3. Release the clamp (B) and take
pump out of the bottom strainer
casing.
A
4. Pull suction adapter (D) and inlet
regulator (C) from the pump.
6
C
D
A
A
C
D
C
D
B
E
- English -
Cleaning the pump
1. Remove the screws and pump housing.
2. Pull off the impeller unit and flat seal.
• Note: When pulling out the impeller unit, the
journal bearing may come loose in the motor
housing.
3. Clean all parts in clear water with a brush.
4. Check parts for damage and replace if necessary.
5. Reassemble in the reverse order.
• Note: Check that the journal bearing in
the motor housing is correctly seated. If
necessary, press the journal bearing with the
wide grooves at the front into the seat in the
motor housing.
Storage/Winterization
The unit is frost resistant to -4 °F (minus 20 °C). Should you store the unit outside of the pond, clean it thoroughly with a
soft brush and water, check it for damage, then store immersed in water or filled with water. Do not immerse the power plug
in water!

Wearing parts

The impeller unit is a wearing part and does not fall under the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.

Spare parts

The use of original parts from OASE ensures continued safe and reliable operation of the unit. Please visit our website for
spare parts drawings and spare parts. www.oase-livingwater.com
Troubleshooting
Issue
Cause
The unit is not
No mains voltage
performing its
B
Impeller blocked, pump running dry
suction function
Insufficient
Strainer casing or satellite filter clogged
capacity
Hose blocked
Hose kinked
B
Excessive loss in the hoses due to friction
Pump overload. The capacity is
automatically reduced to protect the
pump.
Unit switches
Strainer casing clogged
E
off after a short
Pump running dry
running period
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
AquaMax Eco Premium 3000 / 40000
AquaMax Eco Premium 2000
Solution
Check mains voltage
Clean pump housing, check supply lines for blockages
Clean
Clean or replace hose
Eliminate kink, replace hose if it is damaged
Reduce hose length to reduce frictional loss
− Clean the pump housing
− Reduce the ambient temperature (e.g. ensure that
the specified water temperature is adhered to, avoid
direct sunlight)
− Ensure adequate ventilation for dry installation
Clean strainer casing
− Check supply lines for blockages
−Vent hoses
− Check connections for leaks